Pn0C
RS-232 Baud Rate Setting
Setting range
0 to 5
Explanation of Settings
Setting
0
2,400 bps
1
4,800 bps
2
9,600 bps
3
19,200 bps
4
38,400 bps
5
57,600 bps
• Use this parameter to select the baud rate for RS-232 communications.
• Baud rate error: ±0.5%.
Pn0D
RS-485 Baud Rate Setting
Setting range
0 to 5
Explanation of Settings
Setting
0
2,400 bps
1
4,800 bps
2
9,600 bps
3
19,200 bps
4
38,400 bps
5
57,600 bps
• Use this parameter to select the baud rate for RS-485 communications.
• Baud rate error: ±0.5%.
Pn0E
Front Key Protection Setting
Setting range
0 to 1
Explanation of Settings
Setting
0
All enabled
1
Limited to Monitor Mode
• Front panel key operations can be limited to Monitor Mode. This function can be used to prevent
unintended changes to parameters because of incorrect key operations.
• Even if this parameter is set to 1, parameters can be changed by using communications.
• Use communications to return this parameter to 0.
Unit
---
Default setting
Explanation
Unit
---
Default setting
Explanation
Unit
---
Default setting
Explanation
5-16 User Parameters
All modes
2
Yes
Power OFF→ON
All modes
2
Yes
Power OFF→ON
All modes
0
Yes
Power OFF→ON