Asr Timer Failure - HP ProLiant Gen9 Troubleshooting Manual

Hide thumbs Also See for ProLiant Gen9:
Table of Contents

Advertisement

102-System Board Failure, CMOS Test Failed.
Audible Beeps: None
Possible Cause: 8237 DMA controllers, 8254 timers, and similar devices.
CAUTION:
board. If you believe the system board requires replacement, contact HP Technical Support
contact
Action: Contact an authorized service provider for system board replacement.
102-System Board Failure, DMA Test Failed
Audible Beeps: None
Possible Cause: 8237 DMA controllers, 8254 timers, and similar devices.
CAUTION:
board. If you believe the system board requires replacement, contact HP Technical Support
contact
Action: Contact an authorized service provider for system board replacement.
102-System Board Failure, Timer Test Failed
Audible Beeps: None
Possible Cause: 8237 DMA controllers, 8254 timers, and similar devices.
CAUTION:
board. If you believe the system board requires replacement, contact HP Technical Support
contact
Action: Contact an authorized service provider for a system board replacement.

104-ASR Timer Failure

Audible Beeps: None
Possible Cause: System board failure.
CAUTION:
board. If you believe the system board requires replacement, contact HP Technical Support
contact
Action: Run Insight Diagnostics and replace failed components as indicated.
162-System Options Not Set
Possible Cause: Configuration is incorrect. The system configuration has changed since the last boot (for
example, the addition of a hard drive,) or a loss of power to the real-time clock has occurred. The real-time
clock loses power if the onboard battery is not functioning correctly.
Action: Press the F1 key to record the new configuration. Run the server setup utility to change the
configuration. If this message persists, you may need to replace the onboard battery.
Only authorized technicians trained by HP should attempt to remove the system
information" on page 399) before proceeding.
Only authorized technicians trained by HP should attempt to remove the system
information" on page 399) before proceeding.
Only authorized technicians trained by HP should attempt to remove the system
information" on page 399) before proceeding.
Only authorized technicians trained by HP should attempt to remove the system
information" on page 399) before proceeding.
("HP
("HP
("HP
("HP
HP ProLiant server errors 50