HP ProLiant Gen9 Troubleshooting Manual page 297

Hide thumbs Also See for ProLiant Gen9:
Table of Contents

Advertisement

cpqSsChassisName
cpqSsChassisTime
cpqFcaAccelBoxIoSlot
cpqFcaCntlrModel
cpqFcaAccelSerialNumber
cpqFcaAccelTotalMemory
Supporting SNMP Trap Description: "Accelerator lost battery power. Data Loss possible."
NT Event ID: 1150 (Hex)0xc435047e (cpqstmsg.dll)
Log Severity: Error (3)
Event Title: External Array Accelerator Battery Failed.
Log Message: The array accelerator board attached to the external controller in I/O slot %5 of array "%4"
is reporting a battery failure.
SNMP Trap: cpqFca2AccelBatteryFailed - 16019 in CPQFCA.MIB
Symptom: External Array Accelerator Board Battery failed. This trap indicates that the agent has detected a
battery failure associated with the Array Accelerator Cache Board.
User Action: Replace the Accelerator Cache Board.
Supporting SNMP Trap Data:
sysName
cpqHoTrapFlags
cpqSsChassisName
cpqSsChassisTime
cpqFcaAccelBoxIoSlot
cpqFcaCntlrModel
cpqFcaAccelSerialNumber
cpqFcaAccelTotalMemory
Supporting SNMP Trap Description: "Battery status is failed."
NT Event ID: 1151 (Hex)0xc435047f (cpqstmsg.dll)
Log Severity: Error (3)
Event Title: External Array Controller Status Change.
Log Message: The external controller in I/O slot %5 of array "%4" has a new status of %6.
SNMP Trap: cpqFca2CntlrStatusChange - 16020 in CPQFCA.MIB
Symptom: External Array Controller Status Change. This trap indicates that the agent has detected a change
in the status of an External Array Controller. The variable cpqFcaCntlrStatus indicates the current controller
status.
User Action: If the controller status is offline(4), access to the storage box has been lost. Check the storage
box and all fibre channel connections for problems.
Supporting SNMP Trap Data: