HP ProLiant Gen9 Troubleshooting Manual page 150

Hide thumbs Also See for ProLiant Gen9:
Table of Contents

Advertisement

NOT_READY - Drive is not ready and will not spin up.
HARDWARE_ERROR - Drive is returning a Hardware Error sense key; controller
unable to get drive back online.
ABORTED_COMMAND - Drive is returning an Aborted Command sense key; controller
unable to get drive back online.
WRITE_PROTECTED - Drive is returning a sense key indicating it is write
protected.
SPIN_UP_FAILURE_IN_RECOVER - "Start Unit" command failed during error
recovery
REBUILD_WRITE_ERROR - Drive failed write command after multiple retries
during rebuild.
TOO_SMALL_IN_HOT_PLUG - Replacement drive is too small for configured
volume(s).
BUS_RESET_RECOVERY_ABORTED - Unable to communicate with drive after multiple
bus resets and retries; may be due to this drive or another drive that is
corrupting the parallel SCSI bus.
REMOVED_IN_HOT_PLUG - Drive has been hot-removed.
INIT_REQUEST_SENSE_FAILED - "Request Sense" command failed during device
discovery/initialization.
INIT_START_UNIT_FAILED - "Start Unit" command failed during device
discovery/initialization.
INQUIRY_FAILED - "Inquiry" command failed after multiple retries.
NON_DISK_DEVICE - Attached device is not a hard disk per its inquiry data.
READ_CAPACITY_FAILED - "Read Capacity" command failed after multiple
retries.
INVALID_BLOCK_SIZE - Drive indicates it is not formatted for 512 bytes per
sector.
HOT_PLUG_REQUEST_SENSE_FAILED - "Request Sense" command failed after drive
hot-added.
HOT_PLUG_START_UNIT_FAILED - "Start Unit" command failed after drive
hot-added)
WRITE_ERROR_AFTER_REMAP - After reassigning a media error reported during
a write command, the write command failed with another media error.
INIT_RESET_RECOVERY_ABORTED - Unable to communicate with drive during
initialization after multiple bus resets and retries; may be due to this drive
or another drive that is corrupting the parallel SCSI bus.
DEFERRED_WRITE_ERROR - Drive with write cache enabled reported that it could
not complete a write command that it previously indicated was successful [lost
data].
MISSING_IN_SAVE_RIS - Could not write to reserved configuration sectors after
multiple retries.
WRONG_REPLACE - A hot-plug tape drive was plugged in as a replacement into
a drive bay that a hard disk was removed from.
HP Smart Array errors 150

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents