HP ProLiant Gen9 Troubleshooting Manual page 64

Hide thumbs Also See for ProLiant Gen9:
Table of Contents

Advertisement

CAUTION:
board. If you believe the system board requires replacement, contact HP Technical Support
contact
Run Insight Diagnostics and replace failed components as indicated.
2.
305- Redundant ROM Error: Both the Primary and Backup System ROMs are invalid
Action: Flash the Primary and Backup System ROMs to the desired revisions. If the server fails to boot,
perform the flash update via iLO.
306- Redundant ROM Error: iLO FW did not set the Primary System ROM
...The error has been corrected. iLO FW may have an issue.
Action: Remove power. If issue persists, update iLO FW. If the issue persists, contact HP service.
307- Fan Failure Detected - Fan X Failed
308- Required Fan NOT Installed – Fan X Missing
Action: Install the indicated fan.
309- Insufficient Fan Solution
...The system does not have the minimum required number of operating fans.
Action: Install the minimum required fans to prevent possible damage to system components.
310- IMPORTANT: Fan Solution Not Redundant
...The system does not have the minimum required operating fans for redundancy.
Action: Install additional fans if redundancy is required.
311- HP Smart Storage Battery Configuration Error
...The system has exceeded the installed battery capacity.
Action: Increase battery capacity or remove battery-backed devices. For more information, see the user
guide.
312- HP Smart Storage Battery X Failure
...Communication with the battery failed and its output may not be enabled.
Action: Verify the battery is properly installed. For more information, see the user guide. If the issue persists,
contact HP support.
313- HP Smart Storage Battery X Failure
...Battery Shutdown Event Code: XXXX
Action: Restart the system. If the issue persists, contact HP support.
314- A critical error occurred prior to this system boot
Action: Check the Integrated Management Log (IML) for possible additional information.
Only authorized technicians trained by HP should attempt to remove the system
information" on page 399) before proceeding.
("HP
HP ProLiant server errors 64