HP ProLiant Gen9 Troubleshooting Manual page 32

Hide thumbs Also See for ProLiant Gen9:
Table of Contents

Advertisement

Controller State: The array controller is operating without a memory board and has
a bad volume position...
...Any configuration command (e.g. logical drive creation, array expansion, etc.) or modification to the controller will
result in the loss of all existing data on the disabled volume(s).
Action: Install a cache memory module.
Controller State: The array controller is operating without a memory board and
contains more logical drives than are supported in the current configuration...
...Any configuration command (e.g. logical drive creation, array expansion, etc.) or modification to the controller will
result in the loss of all existing data on the disabled volume(s).
Action: Install a cache memory module.
Controller State: The array controller is operating without a memory board and has
an invalid physical drive connection...
...Any configuration command (e.g. logical drive creation, array expansion, etc.) or modification to the controller will
result in the loss of all existing data on the disabled volume(s).
Action: Install a cache memory module.
Controller State: The array controller has a configuration that requires more physical
drives than are currently supported...
...You may reconfigure the controller, but the existing configuration and data will be overwritten and potentially lost.
Action: Do one of the following:
If this message is observed after moving a configured array of drives from another controller, then
upgrade the firmware on this controller. Also, check if the cache module is installed. Install the cache
module if not present. If this doesn't solve the problem, power down the server and move the drives back
to the original controller.
If this message is observed without any drive movement, check if the cache module has failed and
replace it if required. If the problem persists, contact HP support
399).
Controller State: The array controller has an unknown disabled configuration status
message...
...Any configuration command (e.g. logical drive creation, array expansion, etc.) or modification to the controller will
result in the loss of all existing data on the disabled volume(s).
Action: Contact HP support
Controller State: The array controller has an unsupported configuration...
...You may reconfigure the controller, but the existing configuration and data will be overwritten and potentially lost.
Action: Do one of the following:
If this message is observed after moving a configured array of drives from another controller, then
upgrade the firmware on this controller. Also, check if the cache module is installed. Install the cache
("HP contact
information" on page 399).
("HP contact
information" on page
HP ProLiant server errors 32

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents