NT Event ID: 1213 (Hex)0x843504bd (cpqstmsg.dll)
Log Severity: Warning (2)
Event Title: Storage System Temperature Status Change.
Log Message: The %6 %7 storage system connected to SCSI bus %5 of the controller in %4 has a new
temperature status of %2.
SNMP Trap: cpqSs5TempStatusChange - 8027 in CPQSTSYS.MIB
Symptom: Storage System Temperature Status Change. The agent has detected a change in the temperature
status of a storage system. The variable cpqSsBoxTempStatus indicates the current temperature status.
User Action: If the temperature status is degraded or failed, shut down the storage system as soon as
possible. Be sure that the storage system environment is being cooled properly and that no components are
overheated.
Supporting SNMP Trap Data:
sysName
cpqHoTrapFlags
cpqSsBoxCntlrHwLocation
cpqSsBoxCntlrIndex
cpqSsBoxBusIndex
cpqSsBoxVendor
cpqSsBoxModel
cpqSsBoxSerialNumber
cpqSsBoxTempStatus
Supporting SNMP Trap Description: "Storage System temperature status changed to
[cpqSsBoxTempStatus]."
NT Event ID: 1214 (Hex)0x843504be (cpqstmsg.dll)
Log Severity: Warning (2)
Event Title: Storage System Fault Tolerant Power Supply Status Change.
Log Message: The fault tolerant power supply in the %6 %7 storage system connected to SCSI bus %5 of the
controller in %4 has a new status of %2.
SNMP Trap: cpqSs5PwrSupplyStatusChange - 8028 in CPQSTSYS.MIB
Symptom: Storage System Fault Tolerant Power Supply Status Change. The agent has detected a change in
the power supply status of a storage system. The variable cpqSsBoxFltTolPwrSupplyStatus indicates the
current power supply status.
User Action: If the power supply status is degraded, restore power or replace the failed power supply.