cpqRackUid
cpqRackPowerSupplyEnclosureName
cpqRackPowerSupplySerialNum
cpqRackPowerSupplyPosition
cpqRackPowerSupplyFWRev
cpqRackPowerSupplySparePartNumber
cpqRackCommonEnclosureSerialNum
cpqRackCommonEnclosureTrapSequenceNum
Supporting SNMP Trap Description: "The power supply [cpqRackPowerSupplyPosition] in enclosure
[cpqRackPowerSupplyEnclosureName] in rack [cpqRackName] has been inserted."
NT Event ID: 1160 (Hex)0x84350488 (cpqsvmsg.dll)
Log Severity: Warning (2)
Event Title: Rack Power Subsystem Not Redundant
Log Message: The rack power subsystem is no longer in a redundant state.
SNMP Trap: cpqRackPowerSubsystemNotRedundant - 22018 in CPQRACK.MIB
Symptom: The rack power subsystem is no longer in a redundant state.
User Action: Replace any failed power supplies as soon as possible to return the system to a redundant state.
Supporting SNMP Trap Data:
sysName
cpqHoTrapFlags
cpqRackName
cpqRackUid
cpqRackPowerEnclosureName
cpqRackCommonEnclosureSerialNum
cpqRackCommonEnclosureTrapSequenceNum
Supporting SNMP Trap Description: "The power subsystem in enclosure [cpqRackPowerEnclosureName] in
rack [cpqRackName] is no longer redundant."
NT Event ID: 1161 (Hex)0x84350489 (cpqsvmsg.dll)
Log Severity: Warning (2)
Event Title: Rack Power Subsystem Input Voltage Problem
Log Message: The rack power supply detected an input line voltage problem.
SNMP Trap: cpqRackPowerSubsystemLineVoltageProblem - 22019 in CPQRACK.MIB
Symptom: The rack power supply detected an input line voltage problem.
User Action: Check the power input for the power supply or replace any failed power supplies as soon as
possible.
Supporting SNMP Trap Data:
Microsoft Windows Event ID and SNMP traps 373