Storage Enclosure On Scsi Bus X Indicated A Door Alert; Storage Enclosure On Scsi Bus X Indicated A Power Supply Failure; Storage Enclosure On Scsi Bus X Indicated An Overheated Condition; Storage Enclosure On Scsi Bus X Is Unsupported With Its Current Firmware Version - HP ProLiant Gen9 Troubleshooting Manual

Hide thumbs Also See for ProLiant Gen9:
Table of Contents

Advertisement

Storage Enclosure on SCSI Bus X has a Cabling Error (Bus Disabled)...
...SOLUTION: The SCSI controller has an internal and external cable attached to the same bus. Please disconnect the
internal or external cable from the controller. If this controller supports multiple buses, the cable disconnected can be
reattached to an available bus.
Description: The current cabling configuration is not supported.
Action: Refer to the server documentation for cabling guidelines, and reconfigure as indicated.

Storage Enclosure on SCSI Bus X Indicated a Door Alert...

...SOLUTION: Be sure that the storage enclosure door is closed or the side panel is properly installed.
Description: The side panel of the external storage unit is open.
Action: Be sure the side panel of the storage unit is securely closed.

Storage Enclosure on SCSI Bus X Indicated a Power Supply Failure...

...SOLUTION: Replace the power supply.
Description: A power supply in the external storage unit has failed.
Action: Replace the power supply.

Storage Enclosure on SCSI Bus X Indicated an Overheated Condition...

...SOLUTION: Make sure all cooling fans are operating properly. Also be sure the operating environment of storage
enclosure is within temperature specifications.
Description: The external storage unit is generating a temperature alert.
Action:
Be sure all fans are connected and operating properly.
1.
Be sure the operating environment of the storage unit is within specifications.
2.
For better airflow, remove any dust buildup from fans or other areas.
3.
Check the server documentation for allowable temperature specifications and additional tips.
4.
If the problem persists, replace the fan.
5.

Storage enclosure on SCSI Bus X is unsupported with its current firmware version...

...SOLUTION: Upgrade the firmware version on the storage enclosure.
Description: The firmware version of the external storage unit is not supported.
Action: Update the storage device to the latest firmware version.

Storage Enclosure on SCSI Bus X Indicated that the Fan Failed...

...SOLUTION: Replace the fan.
Description: The cooling fan located in the external storage unit has failed.
Action: Replace the fan.

Storage Enclosure on SCSI Bus X Indicated that the Fan is Degraded...

...SOLUTION: this condition usually occurs on enclosures with multiple fans and one of those fans has failed. Replace
any fans not operating properly.
HP ProLiant server errors 23