HP ProLiant Gen9 Troubleshooting Manual page 365

Hide thumbs Also See for ProLiant Gen9:
Table of Contents

Advertisement

cpqRackUid
cpqRackCommonEnclosureName
cpqRackCommonEnclosureModel
cpqRackCommonEnclosureSerialNum
cpqRackCommonEnclosureSparePartNumber
cpqRackCommonEnclosureTrapSequenceNum
Supporting SNMP Trap Description: "The enclosure [cpqRackCommonEnclosureName] has been removed
from rack [cpqRackName]."
NT Event ID: 1146 (Hex)0x4435047a (cpqsvmsg.dll)
Log Severity: Information (1)
Event Title: Enclosure Inserted
Log Message: This trap indicates that an enclosure has been inserted into the rack.
SNMP Trap: cpqRackEnclosureInserted - 22004 in CPQRACK.MIB
Symptom: The enclosure has been inserted. This trap indicates that an enclosure has been inserted into the
rack.
User Action: None.
Supporting SNMP Trap Data:
sysName
cpqHoTrapFlags
cpqRackName
cpqRackUid
cpqRackCommonEnclosureName
cpqRackCommonEnclosureModel
cpqRackCommonEnclosureSerialNum
cpqRackCommonEnclosureSparePartNumber
cpqRackCommonEnclosureTrapSequenceNum
Supporting SNMP Trap Description: "The enclosure [cpqRackCommonEnclosureName] has been inserted
into rack [cpqRackName]."
NT Event ID: 1147 (Hex)0xc435047b (cpqsvmsg.dll)
Log Severity: Error (3)
Event Title: Rack Enclosure Overheated
Log Message: This trap indicates that an enclosure temperature sensor has been tripped indicating an
overheat condition.
SNMP Trap: cpqRackEnclosureTempFailed - 22005 in CPQRACK.MIB
Symptom: The enclosure temperature status has been set to failed. This trap indicates that an enclosure
temperature sensor has been tripped, indicating an overheat condition.
Microsoft Windows Event ID and SNMP traps 365