HP ProLiant Gen9 Troubleshooting Manual page 132

Hide thumbs Also See for ProLiant Gen9:
Table of Contents

Advertisement

The external Smart Array controller is attached to the host side Smart Array
controller <controller name / slot information>.
Message Id: 24705
Severity: Warning
Log message: The external Smart Array controller located in the MSA chassis labeled
as <chassis label> is indicating that sensor number <sensor number> has reported
that the internal temperature is nearing the preset temperature limit. The
external Smart Array controller may enact precautionary measures to prevent data
loss should the temperature reach the operating limit.
The external Smart Array controller is attached to the host side Smart Array
controller <controller name / slot information>.
Message Id: 24706
Severity: Informational
Log message: The external Smart Array controller located in the MSA chassis labeled
as <chassis label> is indicating that sensor number <sensor number> has reported
that a previously existing temperature condition has been corrected. All of the
temperature sensors in the attached box are now reporting acceptable temperature
levels.
The external Smart Array controller is attached to the host side Smart Array
controller <controller name / slot information>.
Message Id: 24707
Severity: Warning
Log message: The external Smart Array controller located in the MSA chassis labeled
as <chassis label> has reported that redundant power supply number <power supply
number> has reported a fault.
The external Smart Array controller is attached to the host side Smart Array
controller <controller name / slot information>.
Message Id: 24708
Severity: Informational
Log message: The external Smart Array controller located in the MSA chassis labeled
as <chassis label> has reported that redundant power supply number <power supply
number> is no longer sensed as being in a failed state. Some possible reasons
that would cause this state change to occur include:
1. The previously failed power supply has returned to an operational state.
2. The previously failed power supply was removed from the chassis.
The external Smart Array controller is attached to the host side Smart Array
controller <controller name / slot information>.
Message Id: 24709
Severity: Error
Log message: The external Smart Array controller located in the MSA chassis labeled
as <chassis label> is reporting a drive failure notification for the <drive type>
physical hard drive located in bay <bay number>. The failure reason received from
the HP Smart Array firmware is: <firmware error code>.
The external Smart Array controller is attached to the host side Smart Array
controller <controller name / slot information>.
HP Smart Array errors 132