HP ProLiant Gen9 Troubleshooting Manual page 137

Hide thumbs Also See for ProLiant Gen9:
Table of Contents

Advertisement

to
Status: <previous status>
The external Smart Array controller is attached to the host side Smart Array
controller <controller name / slot information>.
<previous status> and <current status> values:
"OK"
"FAILED"
"NOT CONFIGURED"
"INTERIM RECOVERY MODE"
"READY FOR RECOVERY"
"RECOVERING"
"WRONG PHYSICAL DRIVE REPLACED"
"PHYSICAL DRIVE NOT PROPERLY CONNECTED"
"HARDWARE IS OVERHEATING"
"HARDWARE HAS OVERHEATED"
"EXPANDING"
"NOT YET AVAILABLE"
"QUEUED FOR EXPANSION"
"DISABLED DUE TO SCSI ID CONFLICT"
"EJECTED"
"ERASING"
"UNKNOWN"
Message Id: 24713
Severity: Informational
Log message: The external Smart Array controller located in the MSA chassis labeled
as <chassis label> has reported that logical drive <logical drive number> is in
a failed state but has had one or more drive replacements and is now ready to
change to a status of "OK".
the logical drive is re-enabled. Please re-enable the logical drive either via
the HP Array Configuration Utility or by power cycling the MSA chassis.
The external Smart Array controller is attached to the host side Smart Array
controller <controller name / slot information>.
Message Id: 24714
Severity: Warning
Log message: The external Smart Array controller located in the MSA chassis labeled
as <chassis label> has reported that the recovery of logical drive <logical drive
number> was aborted while rebuilding due to an unrecoverable read error. Physical
drive number <physical drive number 1> was the replacement drive being rebuilt
before the read error occurred, while physical drive number <physical drive number
2> is the error drive which reported the read error.
However, this status change will not occur until
HP Smart Array errors 137