HP ProLiant Gen9 Troubleshooting Manual page 359

Hide thumbs Also See for ProLiant Gen9:
Table of Contents

Advertisement

Symptom: The Fault Tolerant Fan condition has been set to failed for the specified chassis and fan.
Supporting SNMP Trap Data:
sysName
cpqHoTrapFlags
cpqHeFltTolFanChassis
cpqHeFltTolFanIndex
Supporting SNMP Trap Description: "The Fan Failed on Chassis [cpqHeFltTolFanChassis], Fan
[cpqHeFltTolFanIndex]."
NT Event ID: 1131 (Hex)0x8435046b (cpqsvmsg.dll)
Log Severity: Warning (2)
Log Message: The Fan Sub-system has lost redundancy. Replace any failed or missing fans.
SNMP Trap: cpqHe3FltTolFanRedundancyLost - 6037 in CPQHLTH.MIB
Symptom: The Fault Tolerant Fans have lost redundancy for the specified chassis.
Supporting SNMP Trap Data:
sysName
cpqHoTrapFlags
cpqHeFltTolFanChassis
Supporting SNMP Trap Description: "The Fans are no longer redundant on Chassis
[cpqHeFltTolFanChassis]."
NT Event ID: 1132 (Hex)0x4435046c (cpqsvmsg.dll)
Log Severity: Information (1)
Log Message: Fan Inserted. A hot-plug fan has been inserted into the system.
SNMP Trap: cpqHe3FltTolFanInserted - 6038 in CPQHLTH.MIB
Symptom: A Fault Tolerant Fan has been inserted into the specified chassis and fan location.
Supporting SNMP Trap Data:
sysName
cpqHoTrapFlags
cpqHeFltTolFanChassis
cpqHeFltTolFanIndex
Supporting SNMP Trap Description: "The Fan Inserted on Chassis [cpqHeFltTolFanChassis], Fan
[cpqHeFltTolFanIndex]."
NT Event ID: 1133 (Hex)0x8435046d (cpqsvmsg.dll)
Log Severity: Warning (2)
Log Message: Fan Removed. A hot-plug fan has been removed from the system.
SNMP Trap: cpqHe3FltTolFanRemoved - 6039 in CPQHLTH.MIB
Symptom: A Fault Tolerant Fan has been removed from the specified chassis and fan location.
Microsoft Windows Event ID and SNMP traps 359