Message Id: 24793
Severity: Informational
Log message: Array controller <controller name / slot information> has reported that
a previously existing temperature condition on the controller from sensor <sensor
number> has been corrected. All of the temperature sensors are now reporting
acceptable temperature levels.
Message Id: 24794
Severity: Error
Log message: The external Smart Array controller located in the MSA chassis labeled
as <chassis number> is indicating that sensor number <sensor number> has reported
that the internal temperature of <internal temperature>°C has exceeded the preset
temperature limit of <temperature limit>°C. The external Smart Array controller
may attempt to shut down power to and/or spin down installed disk drives.
The external Smart Array controller is attached to the host side Smart Array
controller <controller name / slot information>.
Message Id: 24795
Severity: Warning
Log message: The external Smart Array controller located in the MSA chassis labeled
as <chassis label> is indicating that its internal temperature is nearing the
preset temperature limit of <temperature limit>°C. The current temperature is
<current temperature>°C as reported by sensor number <sensor number>. The
external Smart Array controller may enact precautionary measures to prevent data
loss should the temperature reach the operating limit.
The external Smart Array controller is attached to the host side Smart Array
controller <controller name / slot information>.
Message Id: 24796
Severity: Informational
Log message: The external Smart Array controller located in the MSA chassis labeled
as <chassis label> is indicating that a previously existing temperature condition
on the controller from sensor <sensor number> has been corrected. All of the
temperature sensors are now reporting acceptable temperature levels.
The external Smart Array controller is attached to the host side Smart Array
controller <controller name / slot information>.
Message Id: 24797
Severity: Informational
Log message: The <drive type> physical drive located in bay <bay number> has passed
a pre-defined usage threshold. It currently has <days or percent> <days of /
percentage> usage remaining. Indicates that the drive is approaching the maximum
usage limit for writes (wear out). This drive can be found in box <box number>
which is connected to port <port number> of the array controller <controller name
/ slot information>.
Message Id: 24798
Severity: Informational
HP Smart Array errors 155