284- DIMM Failure – Uncorrectable Memory Error – Processor X, DIMM Y
Action: Replaced failed DIMM.
284- DIMM Failure – Uncorrectable Memory Error – Memory Board X, DIMM Y
Action: Replaced failed DIMM.
285- DIMM Failure – Uncorrectable Memory Error – Processor X, DIMM Y or
Processor X, DIMM Z
...(exact DIMM could not be determined).
Action: Attempt to isolate which DIMM is failed and replace it.
285- DIMM Failure – Uncorrectable Memory Error – Memory Board X, DIMM Y or
Processor X, DIMM Z
...(exact DIMM could not be determined).
Action: Attempt to isolate which DIMM is failed and replace it.
286- IMPORTANT: The removal of a storage device has been detected
...The device has been removed from the Boot Controller Order.
Action: No action required
287- IMPORTANT: The removal of a network device has been detected
...The device has been removed from the Standard Boot Order (IPL).
Action: No action required
288- IMPORTANT: A new storage device has been detected and has been added to
the end of the Boot Controller Order
Action: No action required
289- IMPORTANT: A new network or storage device has been detected
...This device will not be shown in the Legacy BIOS Boot Order options in RBSU until the system has booted once.
Action: No action required
290- IMPORTANT: The Boot Mode for the system has been changed to Legacy Boot
Mode
...The Legacy BIOS Boot Order options are not configurable until the system has booted once.
Action: No action required
291- IMPORTANT: The Standard Boot Order (IPL) has been detected as corrupted
and has been restored to default values
Action: No action required. Configure the Standard Boot Order (IPL) in RBSU if changes are desired.
HP ProLiant server errors 61