A Physical Disk Installation And Replacement; Overview; Sas Physical Disk Failure Indicators (For Internal Disks Connected To Smart Array Controllers) - HP Smart Array -UX 11i v2 Support Manual

Sas controllers for integrity servers
Hide thumbs Also See for Smart Array HP-UX 11i v2:
Table of Contents

Advertisement

A Physical disk installation and replacement

This appendix discusses the procedure for replacing physical disks in an array.

Overview

When a physical disk fails, the logical drive it belongs to is affected. Each logical drive connected
to a Smart Array Controller can be configured with a different RAID level. Logical drives can be
affected differently by a physical disk failure, depending on their configured RAID level.
The effects of physical disk failure for each RAID level are:
RAID 0
RAID 1
RAID 1+0
RAID 5
RAID 50
RAID ADG
RAID 60
If more physical disks fail than the RAID level supports, fault tolerance is compromised and the
logical drive fails. All requests from the operating system are rejected with unrecoverable errors.
For steps to recover from this situation, see
SAS physical disk failure indicators (for internal disks connected to Smart
Array controllers)
The LEDs on the front of each physical disk are visible through the front of the server. When a
physical disk is configured as part of an array and is attached to a powered-on controller, you
can determine the status of the disk from the illumination pattern of the LEDs.
Figure 16 SAS Physical Disk Status LED Indicators
102 Physical disk installation and replacement
Cannot tolerate disk drive failure. If any physical disk in the array fails, the logical
drive also fails.
Tolerates one physical disk failure.
Tolerates multiple physical disk failures if no failed disks are mirrored to one another.
Tolerates one physical disk failure.
Tolerates one physical disk failure per RAID 5 parity group.
Tolerates simultaneous failure of two physical disks.
Tolerates simultaneous failure of two physical disks per RAID ADG parity group.
"Compromised fault tolerance" (page