Logical drive state: The logical drive is offline from being ejected.
Action: Reinstall the removed physical drives.
Logical drive state: The logical drive is queued for erase.
Action: No action is required. Logical drive migrate and extend operations are not possible while the erase
operation is in progress.
Logical drive state: The logical drive is queued for expansion.
Action: No action is required.
Logical drive state: The logical drive is queued for rebuilding.
Action: No action is required. Normal operations can occur; however, performance will be less than optimal
during the rebuild process.
Logical drive state: This logical drive has a high physical drive count...
...as well as a high stripe size value such that a controller lock up could occur. It is recommended that the stripe size be
migrated to a lower value.
Action: Migrate the stripe size to a lower value using the HP SSA.
NVRAM Error: Board ID could not be read...
...(Read-Only Table failed checksum test). Unrecoverable error.
Action: Contact HP support
NVRAM Error: Bootstrap NVRAM image failed checksum test,...
...but a backup image was found and successfully restored. A system restart is needed.
Action: Restart the server.
NVRAM Error: Bootstrap NVRAM image failed checksum test...
...and could not be restored. This error may or may not be recoverable. A firmware update might be able to correct the
error.
Action: Update the controller firmware. If the update fails, contact HP support
page 399).
Physical Drive State: The data on the physical drive is being rebuilt.
Action: No action is required. Normal operations can occur; however, performance will be less than optimal
during the rebuild process.
Physical Drive State: Predictive failure. This physical drive is predicted to fail soon.
Action: If this drive is part of a non-fault-tolerant configuration, do the following:
Back up all data on the drive.
1.
Replace the drive.
2.
("HP contact
information" on page 399).
("HP contact
information" on
HP ProLiant server errors 35
Need help?
Do you have a question about the ProLiant Gen9 and is the answer not in the manual?