Supporting SNMP Trap Data:
•
sysName
•
cpqHoTrapFlags
•
cpqHeFltTolPowerSupplyChassis
Supporting SNMP Trap Description: "The Power Supplies are now redundant on Chassis
[cpqHeFltTolPowerSupplyChassis]."
NT Event ID: 1030 (Hex) 0x44350406 (cpqsvmsg.dll)
Log Severity: Information (1)
Log Message: The Fan Sub-system has returned to a redundant state.
SNMP Trap: cpqHe3FltTolFanRedundancyRestored - 6055 in CPQHLTH.MIB
Symptom: The Fault Tolerant Fans have returned to a redundant state for the specified chassis.
Supporting SNMP Trap Data:
•
sysName
•
cpqHoTrapFlags
•
cpqHeFltTolFanChassis
Supporting SNMP Trap Description: "The Fans are now redundant on Chassis [cpqHeFltTolFanChassis]."
NT Event ID: 1035 (Hex) 0x8435040BL (cpqsvmsg.dll)
Log Severity: Warning (2)
Log Message: Corrected/uncorrected memory errors detected. The errors have been corrected, but the
memory module should be replaced. Value 0 for CPU means memory is not Processor based.
SNMP Trap: cpqHe5CorrMemReplaceMemModule - 6064 in CPQHLTH.MIB
Symptom: Corrected Memory Errors Detected. The errors have been corrected, but the memory module
should be replaced. Value 0 for CPU means memory is not processor-based.
Supporting SNMP Trap Data:
•
sysName
•
cpqHoTrapFlags
•
cpqHeResMem2BoardNum
•
cpqHeResMem2CpuNum
•
cpqHeResMem2RiserNum
•
cpqHeResMem2ModuleNum
•
cpqHeResMem2ModulePartNo
•
cpqHeResMem2ModuleSize
•
cpqSiServerSystemId
Supporting SNMP Trap Description: "Correctable memory errors require a replacement of the memory
module in slot [cpqHeResMem2BoardNum], socket [cpqHeResMem2ModuleNum], Cpu
[cpqHeResMem2CpuNum] Riser [cpqHeResMem2RiserNum]." Correctable/uncorrectable memory errors
Microsoft Windows Event ID and SNMP traps 344