Event identifier: cpqnimsg.dll - 1038 (Hex)0x8435040e (Service Event)
Log Severity: Warning (2)
Log Message: The Management Agent service is not running. The SNMP Management Agent has
determined that the Management Agent service is not running. Stop the SNMP service and restart the
Management Agents service. If the error persists, reinstalling the Management Agents may correct this error.
Event identifier: cpqnimsg.dll - 1039 (Hex)0x4435040f (Service Event)
Log Severity: Information (1)
Log Message: The NIC SNMP Management Agent has determined the Insight Agent Management service is
running.
Event identifier: cpqnimsg.dll - 1040 (Hex)0x44350410 (Service Event)
Log Severity: Information (1)
Log Message: The agent could not deliver trap %1. The agent was unable to use Asynchronous Management
to deliver a trap. This can be caused by a failure in the Remote Access Service or by a missing or invalid
configuration. Use the Insight Agent control panel to verify the Asynchronous Management configuration
settings. Use the Network control panel to verify the Remote Access configuration. If this error persists,
reinstalling the Insight Agents or the Remote Access Service may correct this error. For more information, see
the Insight Asynchronous Management documentation.
NT Event ID: 1282 (Hex)0x44350502 (cpqnimsg.dll)
Log Severity: Information (1)
Log Message: Redundancy has been increased by the NIC in slot %1, port %2. Number of functional NICs
in the team: %3.
SNMP Trap: cpqNicRedundancyIncreased - 18003 in CPQNIC.MIB
Symptom: This trap is sent any time a previously failed physical adapter in a connected logical adapter
group returns to the OK condition. This trap is not sent when a logical adapter group has connectivity
restored from a Failed condition. The cpqNicConnectivityRestored trap is sent instead. This can be caused by
replacing a faulty cable or by connecting a cable that was disconnected.
User Action: None required.
Supporting SNMP Trap Data:
sysName
cpqHoTrapFlags
cpqNicIfPhysAdapterSlot
cpqNicIfPhysAdapterPort
cpqNicIfLogMapAdapterOKCount
Supporting SNMP Trap Description: "Redundancy increased by adapter in slot [cpqNicIfPhysAdapterSlot],
port [cpqNicIfPhysAdapterPort]."
NT Event ID: 1283 (Hex)0xc4350503 (cpqnimsg.dll)
Log Severity: Error (3)
Log Message: Redundancy has been reduced by the NIC in slot %1, port %2. Number of functional NICs in
the team: %3.