HP ProLiant Gen9 Troubleshooting Manual page 285

Hide thumbs Also See for ProLiant Gen9:
Table of Contents

Advertisement

Supporting SNMP Trap Data:
sysName
cpqHoTrapFlags
cpqDaPhyDrvCntlrIndex
cpqDaPhyDrvBusNumber
cpqDaPhyDrvBay
cpqDaPhyDrvModel
cpqDaPhyDrvFWRev
cpqDaPhyDrvSerialNum
Supporting SNMP Trap Description: "Factory threshold passed for a physical drive."
NT Event ID: 1062 (Hex)0xc4350426 (cpqstmsg.dll)
Log Severity: Error (3)
Event Title: Drive Array Logical Drive Status Change.
Log Message: Logical drive number %5 on the array controller in slot %4 has a new status of %2.
SNMP Trap: cpqDa3LogDrvStatusChange - 3008 in CPQIDA.MIB
Symptom: Logical Drive Status Change. This trap indicates that the agent has detected a change in the status
of a drive array logical drive. The variable cpqDaLogDrvStatus indicates the current logical drive status.
Supporting SNMP Trap Data:
sysName
cpqHoTrapFlags
cpqDaLogDrvStatus
Supporting SNMP Trap Description: "Status is now [cpqDaLogDrvStatus]."
NT Event ID: 1063 (Hex)0xc4350427 (cpqstmsg.dll)
Log Severity: Error (3)
Event Title: Drive Array Spare Drive Status Change.
Log Message: The spare drive in slot %4, port %5, bay %6 has a new status of %2.
SNMP Trap: cpqDa4SpareStatusChange - 3017 in CPQIDA.MIB
Symptom: Spare Drive Status Change. This trap indicates that the agent has detected a change in the status
of a drive array spare drive. The variable cpqDaSpareStatus indicates the current spare drive status.
User Action: If the spare drive status is failed, replace the drive.
Supporting SNMP Trap Data:
sysName
cpqHoTrapFlags
cpqDaSpareStatus
cpqDaSpareCntlrIndex
cpqDaSpareBusNumber
Microsoft Windows Event ID and SNMP traps 285

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents