HP ProLiant Gen9 Troubleshooting Manual page 68

Hide thumbs Also See for ProLiant Gen9:
Table of Contents

Advertisement

Audible Beeps: None
Possible Cause: Required fans are missing or not spinning.
Action:
Check the fans to be sure they are installed and working.
1.
Be sure the assembly is properly connected and each fan is properly seated.
2.
If the problem persists, replace the failed fans.
3.
If a known working replacement fan is not spinning, replace the assembly.
4.
1611-CPU Zone Fan Assembly Failure Detected. Single fan...
...failure. Assembly will provide adequate cooling.
Audible Beeps: None
Possible Cause: Required fan is not spinning.
Action: Replace the failed fan to provide redundancy, if applicable.
1611-Fan Failure Detected
Possible Cause: Required fan is not installed or spinning.
Action:
Check the fans to be sure they are working.
1.
Be sure each fan cable is properly connected and each fan is properly seated.
2.
If the problem persists, replace the failed fans.
3.
1611-Fan x Failure Detected (Fan Zone CPU)
Possible Cause: Required fan is not installed or spinning.
Action:
Check the fans to be sure they are working.
1.
Be sure each fan cable is properly connected, if applicable, and each fan is properly seated.
2.
If the problem persists, replace the failed fans.
3.
1611-Fan x Failure Detected (Fan Zone I/O)
Possible Cause: Required fan is not installed or spinning.
Action:
Check the fans to be sure they are working.
1.
Be sure each fan cable is properly connected, if applicable, and each fan is properly seated.
2.
If the problem persists, replace the failed fans.
3.
HP ProLiant server errors 68

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents