SNMP Trap: cpqIdeDriveOk - 14002 in CPQIDE.MIB
Symptom: An IDE drive status has been set to OK.
User Action: None.
Supporting SNMP Trap Data:
sysName
cpqHoTrapFlags
cpqIdeIdentIndex
Supporting SNMP Trap Description: "IDE drive [cpqIdeIdentIndex] has returned to normal operating
condition."
NT Event ID: 1145 (Hex)0xc4350479 (cpqstmsg.dll)
Log Severity: Error (3)
Event Title: External Array Logical Drive Status Change.
Log Message: Logical drive number %5 on array "%4" has a new status of %6.
SNMP Trap: cpqExtArrayLogDrvStatusChange - 16022 in CPQFCA.MIB
Symptom: External Array Logical Drive Status Change. This trap indicates that the agent has detected a
change in the status of an External Array logical drive. The variable cpqFcaLogDrvStatus indicates the current
logical drive status.
User Action: If the logical drive status is failed, examine the array for failed drives that need replacement.
Supporting SNMP Trap Data:
sysName
cpqHoTrapFlags
cpqSsChassisName
cpqSsChassisTime
cpqFcaLogDrvBoxIndex
cpqFcaLogDrvIndex
cpqFcaLogDrvStatus
cpqFcaLogDrvOsName
cpqFcaLogDrvFaultTol
cpqFcaLogDrvSize
Supporting SNMP Trap Description: "Status is now [cpqFcaLogDrvStatus]."
NT Event ID: 1146 (Hex)0xc435047a (cpqstmsg.dll)
Log Severity: Error (3)
Event Title: External Array Physical Drive Status Change.
Log Message: The physical drive in port %5, bay %6 on array "%4" has a new status of %7.
SNMP Trap: cpqFca2PhyDrvStatusChange - 16016 in CPQFCA.MIB
Microsoft Windows Event ID and SNMP traps 294