HP ProLiant Gen9 Troubleshooting Manual page 302

Hide thumbs Also See for ProLiant Gen9:
Table of Contents

Advertisement

Symptom: Tape Library Door Closed. The Insight Agent has detected that the door on an autoloader has
closed.
Supporting SNMP Trap Data:
sysName
cpqHoTrapFlags
cpqTapeLibrarySerialNumber
Supporting SNMP Trap Description: "Tape library [cpqTapeLibrarySerialNumber] door closed."
NT Event ID: 1161 (Hex)0xc4350489 (cpqstmsg.dll)
Log Severity: Error (3)
Event Title: SCSI CD Library Status Change.
Log Message: The CD Library with SCSI target %6 connected to SCSI bus %5 of the controller in slot %4 has
a new status of %2.
SNMP Trap: cpqScsiCdLibraryStatusChange - 5015 in CPQSCSI.MIB
Symptom: CD Library Status Change. The Insight Agent has detected a change in the status of a CD Library
device. The current CD Library status is indicated in the cpqScsiCdLibraryStatus variable.
Supporting SNMP Trap Data:
sysName
cpqHoTrapFlags
cpqCdLibraryCntlrIndex
cpqCdLibraryBusIndex
cpqCdLibraryScsiIdIndex
cpqCdLibraryStatus
Supporting SNMP Trap Description: "Status is now [cpqCdLibraryStatus]."
NT Event ID: 1164 (Hex)0x8435048c (cpqstmsg.dll)
Log Severity: Warning (2)
Event Title: Drive Array Controller Status Change.
Log Message: The Drive Array Controller in slot %4 has a new status of %5.
SNMP Trap: cpqDa5CntlrStatusChange - 3028 in CPQIDA.MIB
Symptom: Controller Status Change. This trap indicates that the agent has detected a change in the status of
a drive array controller. The variable cpqDaCntlrBoardStatus indicates the current controller status.
User Action: If the board status is generalFailure(3), you may need to replace the controller. If the board
status is cableProblem(4), check the cable connections between the controller and the storage system.
Supporting SNMP Trap Data:
sysName
cpqHoTrapFlags
cpqDaCntlrSlot
cpqDaCntlrBoardStatus