HP ProLiant Gen9 Troubleshooting Manual page 327

Hide thumbs Also See for ProLiant Gen9:
Table of Contents

Advertisement

sysName
cpqHoTrapFlags
cpqDaCntlrHwLocation
cpqDaPhyDrvCntlrIndex
cpqDaPhyDrvIndex
cpqDaPhyDrvLocationString
cpqDaPhyDrvType
cpqDaPhyDrvModel
cpqDaPhyDrvFWRev
cpqDaPhyDrvSerialNum
cpqDaPhyDrvFailureCode
cpqDaPhyDrvStatus
cpqDaPhyDrvBusNumber
Supporting SNMP Trap Description: "Physical Drive Status is now [cpqDaPhyDrvStatus]."
NT Event ID: 1217 (Hex)0x843504c1 (cpqstmsg.dll)
Log Severity: Warning (2)
Event Title: Drive Array Spare Drive Status Change.
Log Message: The spare drive in %4, %5 has a new status of %2.
SNMP Trap: cpqDa7SpareStatusChange - 3047 in CPQIDA.MIB
Symptom: Spare Drive Status Change. This trap indicates that the agent has detected a change in the status
of a drive array spare drive. The variable cpqDaSpareStatus indicates the current spare drive status.
User Action: If the spare drive status is failed, replace the drive.
Supporting SNMP Trap Data:
sysName
cpqHoTrapFlags
cpqDaCntlrHwLocation
cpqDaSpareCntlrIndex
cpqDaSparePhyDrvIndex
cpqDaSpareStatus
cpqDaSpareLocationString
cpqDaSpareDrvBusNumber
Supporting SNMP Trap Description: "Spare Status is now [cpqDaSpareStatus]."
NT Event ID: 1218 (Hex)0x843504c2 (cpqstmsg.dll)
Log Severity: Warning (2)
Event Title: Storage System Fan Status Change.
Log Message: The %6 %7 storage system connected to %5 of the controller in%4 has a new status of %2.
Microsoft Windows Event ID and SNMP traps 327