HP ProLiant Gen9 Troubleshooting Manual page 357

Hide thumbs Also See for ProLiant Gen9:
Table of Contents

Advertisement

SNMP Trap: cpqHe4FltTolPowerSupplyFailed - 6050 in CPQHLTH.MIB
Symptom: The fault tolerant power supply condition has been set to failed for the specified chassis and bay
location.
Supporting SNMP Trap Data:
sysName
cpqHoTrapFlags
cpqHeFltTolPowerSupplyChassis
cpqHeFltTolPowerSupplyBay
cpqHeFltTolPowerSupplyStatus
cpqHeFltTolPowerSupplyModel
cpqHeFltTolPowerSupplySerialNumber
cpqHeFltTolPowerSupplyAutoRev
cpqHeFltTolPowerSupplyFirmwareRev
cpqHeFltTolPowerSupplySparePartNum
cpqSiServerSystemId
Supporting SNMP Trap Description: "The Power Supply is Failed on Chassis
[cpqHeFltTolPowerSupplyChassis], Bay [cpqHeFltTolPowerSupplyBay], Status
[cpqHeFltTolPowerSupplyStatus], Model [cpqHeFltTolPowerSupplyModel], Serial Num
[cpqHeFltTolPowerSupplySerialNumber], Firmware [cpqHeFltTolPowerSupplyFirmwareRev]."
NT Event ID: 1126 (Hex)0x84350466 (cpqsvmsg.dll)
Log Severity: Warning (2)
Log Message: The Fault Tolerant Power Supply Sub-system has lost redundancy. Restore power or replace
any failed or missing power supplies.
SNMP Trap: cpqHe3FltTolPowerRedundancyLost - 6032 in CPQHLTH.MIB
Symptom: The Fault Tolerant Power Supplies have lost redundancy for the specified chassis.
Supporting SNMP Trap Data:
sysName
cpqHoTrapFlags
cpqHeFltTolPowerSupplyChassis
Supporting SNMP Trap Description: "The Power Supplies are no longer redundant on Chassis
[cpqHeFltTolPowerSupplyChassis]."
NT Event ID: 1127 (Hex)0x44350467 (cpqsvmsg.dll)
Log Severity: Information (1)
Log Message: Fault Tolerant Power Supply Inserted. A hot-plug fault tolerant power supply has been inserted
into the system.
SNMP Trap: cpqHe3FltTolPowerSupplyInserted - 6033 in CPQHLTH.MIB
Symptom: A Fault Tolerant Power Supply has been inserted into the specified chassis and bay location.
Microsoft Windows Event ID and SNMP traps 357

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents