HP ProLiant Gen9 Troubleshooting Manual page 114

Hide thumbs Also See for ProLiant Gen9:
Table of Contents

Advertisement

Log message: The <drive type> physical hard drive located in bay <bay number> is
not supported <not supported reason>. This drive can be found in box <box number>
which is connected to port <port number> of the array controller <controller name
/ slot information>.
<not supported reason> values:
"because it is a singled ported drive"
"because it is a SATA drive"
"because it is smaller than the drive it is replacing"
"because it is of an unrecognized type"
"because it contains an unsupported RIS configuration"
Message Id: 24598
Severity: Informational
Log message: Logical drive <logical drive number> of array controller <controller
name / slot information> has encountered a status change from:
Status: <previous status>
to
Status: <current status>
<previous status> and <current status> values:
"OK"
"FAILED"
"NOT CONFIGURED"
"INTERIM RECOVERY MODE"
"READY FOR RECOVERY"
"RECOVERING"
"WRONG PHYSICAL DRIVE REPLACED"
"PHYSICAL DRIVE NOT PROPERLY CONNECTED"
"HARDWARE IS OVERHEATING"
"HARDWARE HAS OVERHEATED"
"EXPANDING"
"NOT YET AVAILABLE"
"QUEUED FOR EXPANSION"
"DISABLED DUE TO SCSI ID CONFLICT"
"EJECTED"
"ERASING"
"UNKNOWN"
Message Id: 24599
Severity: Warning
HP Smart Array errors 114