Fatal Front Side Bus Error
Audible Beeps: None
Possible Cause: The processor front-side bus experienced a fatal error.
Action:
Run Insight Diagnostics.
1.
CAUTION:
provided in "Performing processor procedures in the troubleshooting process." Failure to follow
the recommended guidelines can cause damage to the system board requiring replacement of the
system board.
Replace any failed processors or reseat any loose processors.
2.

Fatal Global Protocol Error

Audible Beeps: None
Possible Cause: The system experienced a critical error that caused an NMI.
Action: Run Insight Diagnostics and replace failed components as indicated.

Fatal Hub Link Error

Audible Beeps: None
Possible Cause: The hub link interface has experienced a critical failure that caused an NMI.
Action: Run Insight Diagnostics and replace failed components as indicated.
FATAL ROM ERROR: The System ROM is not Properly Programmed.
Possible Cause: The System ROM is not properly programmed.
Action: Replace the physical ROM part.
Fibre Channel Mezzanine/Balcony Not Supported.
Description: The Fibre Channel adapter is not supported on the server.
Action: Install the supported Fibre Channel adapter.

High Temperature Condition detected by Processor X

Audible Beeps: None
Possible Cause: Ambient temperature exceeds recommended levels, fan solution is insufficient, or fans have
failed.
Action: Adjust the ambient temperature, install fans, or replace the failed fans.
Before replacing or reseating any processors, be sure to follow the guidelines