HP AlphaServer ES47 Cli Reference Manual

Server management command line interface
Hide thumbs Also See for AlphaServer ES47:

Advertisement

AlphaServer ES47/ES80/GS1280
Server Management
Command Line Interface
CLI Reference
Version 3.0
October 2003
This document describes the Server Mangagement Command Line Interface
(CLI) to hp AlphaServer ES47/ES80/GS1280 systems.
The CLI provides access to the whole platform at the most fundamental level.
You can display information, such as the system configuration, cabling, and
environmental component status. You can update the firmware and power the
system or a hard partition on or off, as well as halt and reset. You can create
and delete partitions.
The CLI also provides one of the two ways you can access the SRM console or
operating system running within the system or a partition.

Advertisement

Table of Contents
loading

Summary of Contents for HP AlphaServer ES47

  • Page 1 October 2003 This document describes the Server Mangagement Command Line Interface (CLI) to hp AlphaServer ES47/ES80/GS1280 systems. The CLI provides access to the whole platform at the most fundamental level. You can display information, such as the system configuration, cabling, and environmental component status.
  • Page 2 HP shall not be liable for technical or editorial errors or omissions contained herein. The information in this document is provided “as is” without warranty of any kind and is subject to change without notice. The warranties for HP products are set forth in the express limited warranty statements accompanying such products. Nothing herein should be construed as constituting an additional warranty.
  • Page 3 Taiwanese Notice Japanese Notice Canadian Notice (Avis Canadien) Class A Equipment This Class A digital apparatus meets all requirements of the Canadian Interference-Causing Equipment Regulations. Cet appareil numérique de la classe A respecte toutes les exigences du Règlement sur le matériel brouilleur du Canada.
  • Page 5: Table Of Contents

    Contents Contents Chapter 1 How to Access the Server Management CLI............1-1 Access the CLI from the SPM ..................1-1 1.1.1 From the SPM "Actions" Menu Item ............... 1-1 1.1.2 From the SPM Tree View..................1-2 1.1.3 From the SPM Platform View ................. 1-3 Access the CLI from the AMU ..................
  • Page 6 AlphaServer ES47/ES80/GS1280 Server Management CLI Reference 3.22 enable alert ........................3-34 3.23 enable remote........................ 3-35 3.24 enable test ........................3-35 3.25 examine or e ........................3-37 3.26 halt in ..........................3-39 3.27 halt out ........................... 3-41 3.28 hangup........................... 3-43 3.29 help ..........................3-44 3.30 init modem ........................
  • Page 7: How To Access The Server Management Cli

    How to Access the Server Management CLI Chapter 1 How to Access the Server Management CLI 1.1 Access the CLI from the SPM If your site has an AlphaServer Management Station (AMS) running the Server Platform Management (SPM) software, and you have administrator or operator access to it, you can use the SPM window to telnet into the Server Management CLI of a particular platform.
  • Page 8: From The Spm Tree View

    AlphaServer ES47/ES80/GS1280 Server Management CLI Reference 1.1.2 From the SPM Tree View Once you have logged in as a valid SPM user, you can directly right-click on a platform in the tree view to display a pulldown menu from which you can telnet to the Server Management CLI for...
  • Page 9: From The Spm Platform View

    How to Access the Server Management CLI 1.1.3 From the SPM Platform View From the right pane of the SPM window, you can right-click on a platform to display a pulldown menu that allows you to telnet to the Server Management CLI of that particular platform.
  • Page 10: Access The Cli From The Amu

    AlphaServer ES47/ES80/GS1280 Server Management CLI Reference 1.2 Access the CLI from the AMU You can access the Server Management CLI interface from the AlphaServer Management Utility interface as follows: 1. Click on the "Platform" icon in the tree view. (Remember that the AMU is only attached to a single platform at a time.)
  • Page 11: Access The Cli From The Mbm Backplane

    How to Access the Server Management CLI 1.4 Access the CLI from the MBM Backplane You can attach a serial terminal directly to an MBM backplane to access the Server Management CLI. Figure 1-1 shows the serial connector for the MBM backplane on an 8P drawer. Figure 1-1 8-P Drawer MBM Backplane Serial Connector...
  • Page 12 AlphaServer ES47/ES80/GS1280 Server Management CLI Reference Figure 1-2 shows the serial connector for the MBM backplane on a 2P drawer. Figure 1-2 2-P Drawer MBM Backplane Connector...
  • Page 13: Accessing The Server Management Cli From The Srm Console

    How to Access the Server Management CLI 1.5 Accessing the Server Management CLI from the SRM Console If you have accessed the SRM console or operating system for a platform (or for a partition or subpartition within a platform), you can access the Server Management CLI for the platform by entering the escape sequence <Esc><Esc>MBM.
  • Page 15: Command Line Interface

    Command Line Interface Chapter 2 Command Line Interface The server management command line interface (CLI) performs these tasks for the ES80 and GS1280 servers: • Displays system configuration information • Updates firmware • Powers on and off, halts, and resets the system or partition •...
  • Page 16 AlphaServer ES47/ES80/GS1280 Server Management CLI Reference Example 2-1 The “show *” Command Lists All Environment Variables MBM> show * cpu_enabled FFFFFFF diag_mask diag_min_flag esc_sequence ^[^[MBM halt_on_error mfg_mode ocp_text GS1280 srm_auto_connect MBM> The table below lists environment variables. Table 2-1 Environment Variables...
  • Page 17: Partition Naming And Addressing

    It is legal to have the same subpartition name as the hard partition or to have the same subpartition names under different hard partitions. A partition must be addressed by name in the format -hp <hard_partition_name> -sp <sub_partition_name>.
  • Page 18: Conventions

    AlphaServer ES47/ES80/GS1280 Server Management CLI Reference 2.4 Conventions Convention Meaning Fixed- Examples are shown in a fixed-width font for clarity and to preserve font alignment of output, as they would appear on the console terminal device. Italic Italic type is used to express emphasis.
  • Page 19: Editing

    Command Line Interface 2.6 Editing The following keys can be used in editing Server Management CLI commands: Function Backspace Delete the character; the cursor moves to the left Delete Delete the character; the cursor stays at its position Down arrow Get next command End key Moves the cursor to the end of the command line...
  • Page 20: Online Help

    AlphaServer ES47/ES80/GS1280 Server Management CLI Reference • Command abort. If you get tired of a long and complicated command display or action, type CTRL/C ( ^C). The command is aborted mid-stream. For example: MBM> sh fru Fru Name E Part #...
  • Page 21: Mbm Failsafe Loader

    Command Line Interface If you issue a command with syntactic errors, an error message followed by the correct command usage is displayed, as shown here: MBM>set time ~CLI-W-(tCLImodem): invalid parameters Usage: set time <date> <time> MBM> 2.8 MBM Failsafe Loader If the main MBM firmware image becomes corrupt, the failsafe loader allows the user to recover the system.
  • Page 22: Updating Firmware Images

    AlphaServer ES47/ES80/GS1280 Server Management CLI Reference 2.8.2 Updating Firmware Images The failsafe loader supports updating of firmware images. In order to update an image on a micro running its failsafe loader, you must specify its cabinet, drawer, and micro type. For...
  • Page 23: Cli Output Messages

    Command Line Interface CLI Output Messages The server management CLI may display messages that are not the result of a user command. The output messages consist of a general format: ~Facility-Severity-(taskName): detailed messages Facility The area that detects the error Severity additional information warning messages...
  • Page 24 AlphaServer ES47/ES80/GS1280 Server Management CLI Reference and 0–F for hex ~CLI-E: numeric value too large The value is overflow. Command-Specific Messages ~CLI-E: illegal target address ~CLI-E: illegal data ~CLI-E: deposit data too large for specified type ~CLI-E: invalid device name...
  • Page 25: Chapter 3 Commands

    Commands Chapter 3 Commands 3.1 Command Summary Command Function assign {component, memory} Assign resources to a partition. bootline Change the bootline used in boot ROMs. build fru Write FRU-specific information to a FRU’s EEPROM. clear {<envar>, alert, display, error, log, Clear the SPMU environment variable, the 'alert port, srmenv} pending’...
  • Page 26 AlphaServer ES47/ES80/GS1280 Server Management CLI Reference set {<envar>, alert, baud, dial, escape, Modify the server management CLI flow, init, membership, password, sys environment. serial num, time} show {<envar>, cables, duo, error, fru, Show specified system information. grid, log, membership, memory, modem,...
  • Page 27: Assign Component

    MBM> assign comp –ca 0 –dr 3 sbb –hp account_dept MBM> 2. Delete the IO attached to CPU2 of the subpartition acct_usa. MBM> assign comp –ca 0 –dr 3 IOP2 –hp account_dept -sp Free_Pool MBM> 3. Add CPU 1 to the subpartition acct_usa.
  • Page 28 AlphaServer ES47/ES80/GS1280 Server Management CLI Reference MBM> assign comp –ca 0 –dr 3 cpu1 –hp account_dept –sp acct_usa MBM> 4. Move IOP1 from a different hard partition, resulting in an error. MBM> assign comp –ca 0 –dr 3 cpu1 –hp account_dept –sp acct_usa ~CLI-E-(tCLImodem) cannot move IOP across different HP MBM>...
  • Page 29: Assign Memory

    Options None Examples 1. Assign 16GB of memory to the subpartition acct_usa. MBM> assign mem 16GB –hp account_dept -sp acct_usa MBM> 2. Assign 2GB of memory to the community. MBM> assign mem 16GB -hp account_dept -com MBM>...
  • Page 30 AlphaServer ES47/ES80/GS1280 Server Management CLI Reference See Also show partition, create partition, assign component...
  • Page 31: Bootline

    Commands 3.4 bootline This command is usually used from the FSL. Changes the boot line used in the boot ROMs. bootline determines the boot device, file name, and, if it is a network boot, the TFTP IP address. If you are configuring to boot over a network and are booting multiple micros simultaneously, configure each “inet on Ethernet”...
  • Page 32: Build Fru

    AlphaServer ES47/ES80/GS1280 Server Management CLI Reference 3.5 build fru Sets the part number and serial number of the FRU. “Inaccessible” errors are usually due to IIC error. FRU can be specified with qualifiers, e.g. 'build fru -cab 0 -draw 2 -duo 1 VRM0.TERM' or with the long format as listed in 'show fru' output, e.g.
  • Page 33 Commands PBM module PCI IO riser DUO module CMM module VRMn.CPU VRM (n = 0-5) for CPUs VRMn.RIMM VRM (n = 0-4) for RIMMs VRM0.TERM VRM for terminator RIMMnc RIMMs (n = 0-9 for slot number, c = 0-1 for CPU processor number) PCI power supply (n = 0-1) PWRn...
  • Page 34 AlphaServer ES47/ES80/GS1280 Server Management CLI Reference Examples 1. Write the manufacture data to the EEPROM of the MBM. MBM> build fru -ca 0 -dr 1 MBM 54-30284-01 NI12312312 MBM> 2. Write the manufacture data to the EEPROM of VRM2.CPU (CPU VRM2) on dual-CPU module 3.
  • Page 35 Commands MBM> build fru -rimm Building RIMM serial numbers..MBM> sh fru Fru Name E Part # Serial # Model/Other CAB0.DRW0.DOCP 00 nightlyFri_0 Fri_43 CAB0.DRW0.MBM 00 partnumber serialnum mbm module CAB0.DRW0.DUO0.CMM 10 nightlyFri_2 Fri_45 CAB0.DRW0.DUO0.DUO 10 nightlyFri_3 Fri_46 CAB0.DRW0.DUO0.RIMM00 06 20-1C872-01 GS1280-32P000L CAB0.DRW0.DUO0.RIMM10 06 20-1C872-01...
  • Page 36: Clear

    AlphaServer ES47/ES80/GS1280 Server Management CLI Reference 3.6 clear Clears the value of a server management environment variable and restores the default value if there is one. Syntax clear <smv>, Arguments The server management environment variable. Wildcard for all server management environment variables.
  • Page 37: Clear Alert

    Commands 3.7 clear alert Clears the current alert condition for the modem dial-out. This command will cause the Server Management CLI on this platform to stop paging the remote operator through the modem. However, it does not prevent server management from issuing alerts to other platform's.
  • Page 38: Clear Display

    AlphaServer ES47/ES80/GS1280 Server Management CLI Reference 3.8 clear display Erases the current display screen on the console terminal. Syntax clear display Arguments None Options None Example Clear the terminal display. MBM> clear display MBM> 3-14...
  • Page 39: Clear Error

    Commands 3.9 clear error Clears the TDD and SDD error log entries and checksum errors in the EEPROM located on the specified FRU. "Inaccessible" are usually due to IIC error. Syntax clear error {{[-cabinet <cabinet> -drawer <drawer> -duo <duo>] <fru_name>}, -all} Arguments fru_nam The FRUs are:...
  • Page 40 AlphaServer ES47/ES80/GS1280 Server Management CLI Reference Examples 1. This command clears all TDD and SDD errors from a FRU’s EEPROM. Use the show error command to find the proper FRU name and to verify that errors have been cleared. MBM> show error...
  • Page 41: Clear Log

    Commands 3.10 clear log Erases all error log entries in the MBM and PBM flash. (It takes a few seconds to erase each flash.) Syntax clear log {{[-cabinet <cabinet> -drawer <drawer>] {MBM, PBM}}, -all} Arguments None Options None Examples 1. Clear the error log of the MBM in cabinet 0, drawer 0. MBM>...
  • Page 42: Clear Port

    AlphaServer ES47/ES80/GS1280 Server Management CLI Reference 3.11 clear port Clears the serial port. Syntax clear port Arguments None Options None Example Reset the server management CLI port. MBM> clear port MBM> See Also set baud, set flow 3-18...
  • Page 43: Clear Srmenv

    Commands 3.12 clear srmenv Clears the SRM environment variables. You can clear SRM variables for all partitions, by hard partition, or by a specific subpartition. Syntax clear srmenv {-hp <hard partition> [-sp <subpartition>], -all} Arguments None Options hp <hard partition>...
  • Page 44: Config Cables

    AlphaServer ES47/ES80/GS1280 Server Management CLI Reference 3.13 config cables Adds a new cable or verifies the configuration of all cables. This command assists in locating the proper connector pair to connect the cable. The LEDs at each connector are lit until the next connection is issued.
  • Page 45 Commands 3. Configure the cable of the south IP port of 8P drawer 1 in cabinet 0. Without providing the destination port, the cabling function finds the matching destination cable according to the mess configuration. The LEDs of both ports are lit. MBM>...
  • Page 46: Connect

    Enter the escape sequence <ESC><ESC>MBM to return to the server management CLI. –hp and –sp are not needed if the system has only one subpartition (excluding Free_Pool). -sp is not needed if there is only one subpartition in a given hard partition.
  • Page 47 Commands 2. Connect to the partition acct_usa and then return to the server management CLI by typing the escape sequence. MBM> connect -hp account_dept –sp acct_usa P00>>> Connecting to partition. Use the sequence ^[^[MBM to return. P00>>> P00>>> ^[^[MBM MBM>...
  • Page 48: Create Partition

    1. Create a hard partition account_dept with a maximum of 8 CPUs, define any subsequently created subpartitions as soft partitions, and request memory striping. MBM> create partition –hp account_dept 8 soft -stripe MBM> 2. Create a subpartition under the hard partition account_dept.
  • Page 49 Commands MBM> create partition –hp account_dept –sp acct_usa MBM> See Also show partition, modify partition, delete partition, assign component, assign memory 3-25...
  • Page 50: Delete Partition

    AlphaServer ES47/ES80/GS1280 Server Management CLI Reference 3.16 delete partition Destroys a partition. Returns all resources of the specified partition to the Free_Pool. The partition(s) being destroyed must be in the halt or power-off state. When the last user-defined subpartition within a hard partition is deleted, a Default_SP within that hard partition is created with no components.
  • Page 51 Commands See Also show partition, save partition, create partition, modify partition 3-27...
  • Page 52: Deposit Or D

    AlphaServer ES47/ES80/GS1280 Server Management CLI Reference 3.17 deposit or d Writes the contents of a storage location. This command enables users to write data to CPU registers, micro memory, micro IO space, or any I C device. In order to access any I...
  • Page 53 Commands 2. Set up configuration register 0 of LM80 on the MBM I C bus, PS controller 1, sub bus 0 with the iic address of 50 hex. MBM> deposit -ca 0 -dr 3 pbm -iic 1/0/50 0 7 3. Write to the MBM memory space MBM>...
  • Page 54: Disable Alert

    AlphaServer ES47/ES80/GS1280 Server Management CLI Reference 3.18 disable alert Turns off the modem dial-out function. This command will only disable the modem dial-out. It does not prevent server management from issuing alerts to other platforms. Getting the remote operator's attention is essential to insure the environmental conditions do not damage the hardware.
  • Page 55: Disable Remote

    Commands 3.19 disable remote Turns off remote access, preventing users from dialing in remotely. Syntax disable remote Arguments None Options None Example Do not allow the remote user to log in. MBM> disable remote #not yet implemented Disabling remote dial-in MBM>...
  • Page 56: Disable Test

    AlphaServer ES47/ES80/GS1280 Server Management CLI Reference 3.20 disable test Turns off a diagnostic test. This will disable certain SRM/XSROM tests from running for debug purpses. Syntax disable test <test_number> Argument test_number The number assigned to a diagnostic test in hex.
  • Page 57 ~PCO-I-(pco_03) Running diagnostics on HP: HP1 [2003/04/10 03:14:38] ~PCO-I-(pco_02) Diagnostics completed on HP: HP0 [2003/04/10 03:14:38] ~PCO-I-(pco_02) HP:HP0 SP:Default_SP Primary is NS:0 EW:0 which is cab:00 drw:0 cpu:0 [2003/04/10 03:14:39] ~PCO-I-(pco_02) Loading SRM on Primary for HP: HP0, SP: Default_SP. [2003/04/10 03:14:43]...
  • Page 58: Enable Alert

    AlphaServer ES47/ES80/GS1280 Server Management CLI Reference 3.22 enable alert Turns on the modem dial-out function. This command is triggered whenever an alert condition occurs. An alert is sent every 30 minutes until either alerts are disabled or the alert is cleared.
  • Page 59: Enable Remote

    Commands 3.23 enable remote Turns on remote access privilege. This command allows remote dial-in to the system. Syntax enable remote Arguments None Options None Example Enable remote access to the system. MBM> enable remote #not yet implemented Enabling remote dial-in MBM>...
  • Page 60 AlphaServer ES47/ES80/GS1280 Server Management CLI Reference Enable XSROM test 12, which is Data Pattern March read/write). MBM> set diag_min_flag on MBM> show diag_mask diag_mask 000000010003000300030000 MBM> enable test 12 MBM> show diag_mask diag_mask 000000010003000300070000 MBM> See Also disable test, show...
  • Page 61: Examine Or E

    Commands 3.25 examine or e Reads the contents of a storage location. This command enables users to read the data from CPU registers, micro memory, micro IO space or any I C device. In order to access any I device, a user must specify the I C controller, sub bus, I C address, and the microprocessor it connects to.
  • Page 62 AlphaServer ES47/ES80/GS1280 Server Management CLI Reference MBM> e * 0/1/cpu3/ipr:11 12341234 43214321 MBM> 2. Read the temperature of the LM80 on the MBM I C bus, PS controller 1, sub bus 0 with the I C address 0x50. MBM> e -ca 0 -dr 3 MBM -iic 1/0/50 27 -b...
  • Page 63: Halt In

    1. Assert system halt to a non-partitioned system or a system with only one subpartition. MBM> halt in MBM> 2. Assert halt to subpartition acct_usa of hard partition account_dept. MBM> halt in -hp account_dept -sp acct_usa MBM> 3. Halt all subpartitions in hard partition account_dept. MBM> halt in -hp account_dept MBM>...
  • Page 64 AlphaServer ES47/ES80/GS1280 Server Management CLI Reference 4. Halt all partitions. MBM> halt in –all MBM> 5. Halt an individual CPU by its physical location (cabinet and drawer). MBM> halt in -ca 0 -dr 2 CPU0 MBM> 6. Halt an individual CPU by its mesh coordinate.
  • Page 65: Halt Out

    1. Deassert system halt to a non-partitioned system. MBM> halt out MBM> 2. Deassert halt to subpartition acct_usa of hard partition account_dept. MBM> halt out -hp account_dept -sp acct_usa MBM> 3. Deassert halt to all subpartitions in hard partition account_dept. MBM> halt out -hp account_dept MBM>...
  • Page 66 AlphaServer ES47/ES80/GS1280 Server Management CLI Reference 4. Deassert halt to all partitions. MBM> halt out -all MBM> 5. Deassert halt to an individual CPU by physical location (cabinet and drawer). MBM> halt out -ca 0 -dr 2 CPU0 MBM> 6. Deassert halt to an individual CPU by mesh coordinate.
  • Page 67: Hangup

    3.28 hangup Terminates a console or telnet session. This command will halt an SRM connect or MBM telnet access session. Syntax hangup {{-hp <hard_partition> [-sp <subpartition>]}, {[-cabinet <cabinet> -drawer <drawer>] {MBM, PBM} <port>}} Arguments -hp <hard_partition> Hard partition name -sp <subpartition>...
  • Page 68: Help

    AlphaServer ES47/ES80/GS1280 Server Management CLI Reference 3.29 help Displays information about server management CLI commands. Describes command conventions and available commands by default; includes a detailed description and syntax for a given command. Syntax help [<command>, *] Arguments command The command to be displayed.
  • Page 69 Commands 2. Help on a particular command. The characters in square brackets ([]) are optional. MBM> help show cable NAME sh[ow] cab[le] FUNCTION Display the cable configuration. SYNOPSIS show cable [-ip | -io] MBM> 3-45...
  • Page 70: Init Modem

    AlphaServer ES47/ES80/GS1280 Server Management CLI Reference 3.30 init modem Initializes the modem using the user-defined initialization string. Syntax init modem Arguments None Options None Examples Initialize the modem and allow remote access to the system if the initialization succeeds. 1. A modem is present and the initialization completes.
  • Page 71: Locate

    Commands 3.31 locate Locate the specified component. This command will cause LEDs to blink in the specified cabinet (blue and yellow LEDs), drawer (yellow LED), or module (yellow LED). The LEDs blink for 30 seconds at one-second intervals to help you locate the component of SBB, PCI, duo, and power. Syntax locate [-cabinet <cabinet>...
  • Page 72: Logout

    AlphaServer ES47/ES80/GS1280 Server Management CLI Reference 3.32 logout Exits from the remote host. This command logs out of the remote host MBM or PBM. If a remote login is active (via telnet), it is stopped. Syntax logout Arguments None Options...
  • Page 73: Mbmboot Or

    Commands 3.33 mbmboot or @ NOTE: This command works only from within the MBM Failsafe Loader. This command boots the main MBM/PBM image from flash or from the network. Syntax mbmboot Arguments None Options None Example Boot the main MBM image FSL>...
  • Page 74 AlphaServer ES47/ES80/GS1280 Server Management CLI Reference Marver Server Management X1.0-11202 Starting up Image built on Apr 16 2002 at 12:52:30 -> Running POST ...0A 0B 0C 0D 0E Cabinet number: 0 Drawer number: 3 Micro type: 0 Node IP address: 10.3.0.1 probeQ: 2ad934 grpTask[i].RcvQ:2ad934…...
  • Page 75: Modify Partition

    3.34 modify partition Modify existing hard partition attributes. This command will change the hard partition attributes, including maximum CPUs and memory striping. Syntax modify partition -hp <hard_partition> {CPU <max_CPUs | stripe {on, off}} Arguments -hp <hard_partition> Hard partition name -CPU <max_CPUs>...
  • Page 76: Power Off

    AlphaServer ES47/ES80/GS1280 Server Management CLI Reference 3.35 power off Turns off the power to a system, component, or partition. This command powers off a non- partitioned system if no arguments are given, or it powers off a specific hard partition or component.
  • Page 77 MBM> 4. Power off all partitions. MBM> power off –all [2003/04/10 03:09:43] ~PCO-I-(pco_04) Preparing to power off partition. HP: HP0 [2003/04/10 03:09:44] ~PCO-I-(pco_00) Preparing to power off partition. HP: HP1 [2003/04/10 03:09:44] ~PCO-I-(pco_03) Preparing to power off partition. HP: HP2 [2003/04/10 03:09:45] ~PCO-I-(pco_01) Preparing to power off partition.
  • Page 78: Power On

    Yankees, and Pedro and Noma in RedSox) issuing either “power on –all”, “power on – hp RedSox”, or “Power on –hp Yankees” will power up the partitions and send the output to the console session. When a user connects to the console session (conn –hp RedSox –sp Pedro) the powerup messages (the grid and diagnostics) will be displayed.
  • Page 79 1. Power on a system with only one hard partition. This is the only case in which the power on command can be used without arguments. MBM> power on [2003/04/16 00:06:30] ~PCO-I-(pco_01) Preparing to power on partition. HP: Default_HP [2003/04/16 00:06:43] ~PCO-I-(pco_01) Configuring for 22 CPUs for HP:0 Default_HP .w..w..w..w..w..w..w..w......
  • Page 80 Running test 50, Loop on Secondary Routine ... on 21 EV7s (SP:Default_SP) [2003/04/16 00:08:41] ~PCO-I-(pco_01) Loading SRM on Primary for HP: Default_HP, SP: Default_SP. Running test 50, Loop on Secondary Routine ... on 0 EV7s (SP:Free_Pool)[2003/04/16 00:08:45] ~PCO-I-(pco_01) Powered On HP:Default_HP MBM>...
  • Page 81 Commands [2003/04/14 14:14:48] ~PCO-I-(pco_01) Diagnostics completed on HP: hp0 [2003/04/14 14:14:48] ~PCO-I-(pco_01) HP:hp0 SP:Default_SP Primary is NS:0 EW:0 which is cab:00 drw:0 cpu:0 [2003/04/14 14:14:48] ~PCO-I-(pco_01) Loading SRM on Primary for HP: hp0, SP: Default_SP. [2003/04/14 14:14:50] ~PCO-I-(pco_02) Powered On HP:hp1...
  • Page 82 AlphaServer ES47/ES80/GS1280 Server Management CLI Reference 8. Power on PCI drawer 2 of cabinet 1. MBM> power on -ca 1 -dr 2 pci MBM> See Also power off, show power, reset, connect 3-58...
  • Page 83: Reset

    Syntax [ {[-cabinet <cabinet> -drawer <drawer>] CPU<n>}, reset {-ew <ew_coord> -ns <ns_coord> CPU}, {{-hp <hard_partition>, -all} [-xsrom] } {-micro {[-cabinet <cabinet> -drawer <drawer>] <micro>}, -all}] Arguments CPU<n> The CPU by cabinet and drawer number. n refers to the CPU number within the 8P drawer and ranges from 0 to 7.
  • Page 84 AlphaServer ES47/ES80/GS1280 Server Management CLI Reference Examples 1. Reset a system with only one hard partition. MBM> reset [2003/04/16 00:06:30] ~PCO-I-(pco_01) Preparing to reset partition. HP: Default_HP [2003/04/16 00:06:43] ~PCO-I-(pco_01) Configuring for 22 CPUs for HP:0 Default_HP .w..w..w..w..w..w..w..w......wP--P--P--F--P--P--P--Fw......|..|..|..|..|..|..|..|......Processor .|..|..|..|..|..|..|..|......Filler wP--P--P--F--P--P--P--Fw.......
  • Page 85 Running test 50, Loop on Secondary Routine ... on 21 EV7s (SP:Default_SP) [2003/04/16 00:08:41] ~PCO-I-(pco_01) Loading SRM on Primary for HP: Default_HP, SP: Default_SP. Running test 50, Loop on Secondary Routine ... on 0 EV7s (SP:Free_Pool) MBM>...
  • Page 86 AlphaServer ES47/ES80/GS1280 Server Management CLI Reference [2003/04/14 14:14:48] ~PCO-I-(pco_01) Loading SRM on Primary for HP: hp0, SP: Default_SP. MBM> MBM> conn -hp hp0 -sp default_sp Connecting to partition. Use the sequence ^[^[MBM to return. ~PCO-I-(pco_01) Preparing to reset partition. HP: hp0...
  • Page 87: Save Partition

    Options -hp <hard_partition> Hard partition name. -all All partitions. Examples 1. Save all subpartitions under the hard partition account_dept. MBM>save partition -hp account_dept MBM> 2. Save all partitions. MBM>save partition MBM>save partition -all MBM> See Also show partition, create partition, delete partition...
  • Page 88: Set

    AlphaServer ES47/ES80/GS1280 Server Management CLI Reference 3.39 set Sets the value of a server management environment variable. This command is analogous to the SRM set command; however, these settings are used to control the behavior of the Server Management subsystem.
  • Page 89: Set Alert

    Commands 3.40 set alert Sets the modem alert string. This string should be set to a meaningful value, such as the system serial number or remote access phone number. The maximum string length is 63 characters. The alert string is sent to the modem after the dial string. Syntax set alert [<alert_string>]...
  • Page 90: Set Baud

    AlphaServer ES47/ES80/GS1280 Server Management CLI Reference 3.41 set baud Changes the serial port baud rate. This command enables users to change the baud rate of the modem port. The baud rate is nonvolatile. Syntax set baud <baud_rate> <modem_baud> <baud_rate> Argument baud_rate The baud rate for the specified channel;...
  • Page 91: Set Dial

    Commands 3.42 set dial Sets the modem dial string. The dial string is the target phone number and any appropriate modem commands required by the target. It is nonvolatile across system resets and power cycles. The maximum string length is 63 characters. The dial string is sent to the modem before the alert string.
  • Page 92: Set Escape

    AlphaServer ES47/ES80/GS1280 Server Management CLI Reference 3.43 set escape Changes the server management CLI escape sequence. This command enables the user to change the escape sequence used for invoking the server management CLI. The escape sequence can be any character string, not to exceed 15 characters, and it is case insensitive.
  • Page 93: Set Flow

    Commands 3.44 set flow Changes the flow control of the modem port. The flow control type is nonvolatile. Syntax set flow <flow_control> <modem_flow> <flow_control> Where modem_flow is a server management environment variable. Argument flow_control The supported flow control types for the modem port: none, software, hardware, or both.
  • Page 94: Set Init

    AlphaServer ES47/ES80/GS1280 Server Management CLI Reference 3.45 set init Sets the initialization string that is sent to the modem when the enable remote command is issued. The initialization string is stored in the MBM’s EEPROM and has a maximum length of 31 characters.
  • Page 95: Set Membership

    Commands 3.46 set membership Set the membership for the MBM/PBM micros. This command will allow the user to add, subtract, or auto detect the set of micros in the system configuration. Use the set membership command to update the current set of micros found on the private LAN.
  • Page 96 AlphaServer ES47/ES80/GS1280 Server Management CLI Reference interrupt: ~GRP-I-(interrupt), GROUP HAS FORMED ID:100010a.d interrupt: ~GRP-I-(interrupt), GROUP IS STABLE ID:100010a.d [2003/04/17 15:51:55] ~REC-W-(trecTask) Server management group is stable. MBM> 2. Example of the “-sub” option MBM> set member -sub -ca 0 -dr 2 pbm...
  • Page 97: Set Password

    Commands 3.47 set password Sets the remote access password. The password has a maximum length of 15 characters. The default password is mvfirmware. The password is nonvolatile and stored in the EEPROM of the MBM or PBM. Syntax set password <password>...
  • Page 98: Set Sys_Serial_Num

    AlphaServer ES47/ES80/GS1280 Server Management CLI Reference 3.48 set sys_serial_num Sets the system serial number. The serial number has a maximum length of 12 characters. This command converts input to upper case and propagates the serial number to all EEPROMs except RIMMs.
  • Page 99: Set Time

    The format is hh:mm:ss. Options None Examples 1. Change the date and time. MBM> set time 2002/04/16 17:20:30 MBM> show time Common base time: 2002/04/16 17:20:34 HP Name SP Name Delta Time (Days hh:mm:ss) Default_SP +00 +00:+00:+00 Default_SP -01 -01:-01:-01 MBM>...
  • Page 100: Shell

    AlphaServer ES47/ES80/GS1280 Server Management CLI Reference 3.50 shell Starts a vxworks shell. Note: This command will be removed when the MBM/PBM firmware is not shipped with the vxworks shell. Syntax shell Arguments None Options None Example Spawn a new shell task to go back to the shell prompt.
  • Page 101: Show

    Commands 3.51 show Displays the value of one or all server management environment variables. Integer variables are displayed in hex. Syntax show {<smv>, *} Arguments The environment variable name. Lists all environment variables if no variable name is provided. List all environment variables. Options None Example...
  • Page 102: Show Cables

    AlphaServer ES47/ES80/GS1280 Server Management CLI Reference 3.52 show cables Displays the cabling configuration. This command shows the physical cabling layout. Interprocessor (IP) cables connect external 8P pairs of CPU routing ports. The six IP ports are two North, two South, one East and one West. There are eight IO cables in a drawer. Each corresponds to an IO7.
  • Page 103 Commands IO cabling between IORs of the PCI drawer and CPU IOPs PCI drawer ------- ------- ------- ------- MBM> See Also config cables 3-79...
  • Page 104: Show Duo

    AlphaServer ES47/ES80/GS1280 Server Management CLI Reference 3.53 show duo Shows the configuration and state of dual processor modules. When calculating the total CPU memory, the RAID RIMMs are excluded. RIMM4 is redundant if RIMMs 0 - 4 are fully populated. RIMM9 is also redundant if RIMMs 5-9 are fully populated.
  • Page 105 Commands RIMM0: 128MB 128MB RIMM1: 128MB 128MB RIMM2: 128MB 128MB RIMM3: 128MB 128MB RIMM4: 0MB (Non-existent) 0MB (Non-existent) RIMM5: 128MB 128MB RIMM6: 128MB 128MB RIMM7: 128MB 128MB RIMM8: 128MB 128MB RIMM9: 0MB (Non-existent) 0MB (Non-existent) CPU Revision: EV7 2.1 EV7 2.1 CPU Cache: 1.5 MB 1.5 MB...
  • Page 106 AlphaServer ES47/ES80/GS1280 Server Management CLI Reference RIMM5: 128MB 128MB RIMM6: 128MB 128MB RIMM7: 128MB 128MB RIMM8: 128MB 128MB RIMM9: 0MB (Non-existent) 0MB (Non-existent) CPU Revision: EV7 2.1 EV7 2.1 CPU Cache: 1.5 MB 1.5 MB CPU Speed: 1000 MHz 1000 MHz...
  • Page 107 Commands CPU Revision: EV7 2.1 EV7 2.1 CPU Cache: 1.5 MB 1.5 MB CPU Speed: 1000 MHz 1000 MHz MBM> 2. Show a specific dual CPU module. MBM> sh duo -ca 0 -dr 1 duo2 DUO2 is in Cabinet 0, Drawer 1, Slot 2 CMM Status: OK Duo Power state: ON CPU4...
  • Page 108: Show Error

    AlphaServer ES47/ES80/GS1280 Server Management CLI Reference 3.54 show error Displays errors logged in the FRU EEPROM. This command will display any TDD failures logged in a FRU's IIC EEPROM. "Inaccessible" is usually due to IIC error. Syntax show error [-cabinet <cabinet> -drawer <drawer>]...
  • Page 109 Commands CAB0.DRW0.DUO1.RIMM81 40 FRU checksum error between bytes 128-254 CAB0.DRW1.DUO0.CMM 10 FRU checksum error between bytes 0-62 CAB0.DRW1.DUO0.RIMM00 40 FRU checksum error between bytes 128-254 CAB0.DRW1.DUO0.RIMM10 40 FRU checksum error between bytes 128-254 CAB0.DRW1.DUO0.RIMM20 40 FRU checksum error between bytes 128-254 CAB0.DRW1.DUO0.RIMM30 40 FRU checksum error between bytes 128-254 CAB0.DRW1.DUO0.RIMM50...
  • Page 110 AlphaServer ES47/ES80/GS1280 Server Management CLI Reference CAB0.DRW3.DUO0.CMM 10 FRU checksum error between bytes 0-62 CAB0.DRW3.DUO0.RIMM00 40 FRU checksum error between bytes 128-254 CAB0.DRW3.DUO0.RIMM10 40 FRU checksum error between bytes 128-254 CAB0.DRW3.DUO0.RIMM20 40 FRU checksum error between bytes 128-254 CAB0.DRW3.DUO0.RIMM30 40 FRU checksum error between bytes 128-254 CAB0.DRW3.DUO0.RIMM50...
  • Page 111 Commands CAB0.DRW1.DUO0.RIMM41 40 FRU checksum error between bytes 128-254 CAB0.DRW1.DUO0.RIMM51 40 FRU checksum error between bytes 128-254 CAB0.DRW1.DUO0.RIMM61 40 FRU checksum error between bytes 128-254 CAB0.DRW1.DUO0.RIMM71 40 FRU checksum error between bytes 128-254 CAB0.DRW1.DUO0.RIMM81 40 FRU checksum error between bytes 128-254 CAB0.DRW1.DUO0.RIMM91 40 FRU checksum error between bytes 128-254 MBM>...
  • Page 112: Show Fru

    AlphaServer ES47/ES80/GS1280 Server Management CLI Reference 3.55 show fru Displays information on every FRU. Syntax show fru [-cabinet <cabinet> -drawer <drawer>] [ -s, -e]] Arguments None Options -cabinet <cabinet> Cabinet number in hex. If not specified, all cabinets are shown.
  • Page 113 Commands CAB0.DRW0.DUO0.VRM3.RIMM 00 nightlyFri_10 Fri_53 7F7FF8 CAB0.DRW0.DUO0.VRM4.RIMM 00 nightlyFri_11 Fri_54 7F7FF8 CAB0.DRW0.DUO0.VRM0.TERM 00 nightlyFri_12 Fri_55 7F7FA2 CAB0.DRW0.DUO1.CMM 10 nightlyFri_13 Fri_56 CAB0.DRW0.DUO1.DUO 10 nightlyFri_14 Fri_57 CAB0.DRW0.DUO1.RIMM00 06 20-1C872-01 GS1280-32P010L CAB0.DRW0.DUO1.RIMM10 06 20-1C872-01 GS1280-32P011L CAB0.DRW0.DUO1.RIMM20 06 20-1C872-01 GS1280-32P012L CAB0.DRW0.DUO1.RIMM30 06 20-1C872-01 GS1280-32P013L CAB0.DRW0.DUO1.RIMM50 06 20-1C872-01 GS1280-32P015L...
  • Page 114 AlphaServer ES47/ES80/GS1280 Server Management CLI Reference CAB0.DRW1.DUO1.RIMM11 06 20-1C872-01 GS1280-32P05BL CAB0.DRW1.DUO1.RIMM21 06 20-1C872-01 GS1280-32P05CL CAB0.DRW1.DUO1.RIMM31 06 20-1C872-01 GS1280-32P05DL CAB0.DRW1.DUO1.RIMM51 06 20-1C872-01 GS1280-32P05FL CAB0.DRW1.DUO1.RIMM61 06 20-1C872-01 GS1280-32P05GL CAB0.DRW1.DUO1.RIMM71 06 20-1C872-01 GS1280-32P05HL CAB0.DRW1.DUO1.RIMM81 06 20-1C872-01 GS1280-32P05IL CAB0.DRW1.DUO1.VRM0.CPU 00 nightlyFri_38 Fri_81 7F7FF8 CAB0.DRW1.DUO1.VRM1.CPU...
  • Page 115 Commands CAB1.DRW3.PS1 00 nightlyFri_114 Fri_157 7F7FA2 CAB1.DRW3.IOR0 00 nightlyFri_115 Fri_158 CAB1.DRW4.DOCP 00 nightlyFri_116 Fri_159 CAB1.DRW4.PBM 00 nightlyFri_117 Fri_160 CAB1.DRW4.PCI 00 nightlyFri_118 Fri_161 CAB1.DRW4.PS1 00 nightlyFri_119 Fri_162 7F7FA2 CAB1.DRW4.IOR0 00 nightlyFri_120 Fri_163 MBM> 3. Display only FRUs with errors in Cabinet 1 MBM>...
  • Page 116: Show Grid

    AlphaServer ES47/ES80/GS1280 Server Management CLI Reference 3.56 show grid Shows the power-on grid for a particular hard partition or all hard partitions. The power-on grid shows how the CPUs interconnect. Options may be omitted if there is only one hard partition.
  • Page 117: Show Log

    Commands 3.57 show log Displays errors logged in the MBM or PBM flash. The events logged might be the following: • Server management micro detected errors • Hardware environmental events. For example, fan, voltage, temperature, power supply failure, etc. • EV7 diagnostic failures •...
  • Page 118 AlphaServer ES47/ES80/GS1280 Server Management CLI Reference -search <string> Extract only text entries that match the given string (case insensitive). If the string contains spaces, please enclose it with double quotes ““. -since <date> Displays entries after a given date, which is in the format yyyy/mm/dd.
  • Page 119 Commands 2. Extract specific entries from a micro. MBM> sh log -ca 0 -dr 0 -start 2 -end 4 Error log from MBM in Cabinet 0, Drawer 0 ------------------------------------------ Entry 2: At 2002/04/17 19:25:18 ~ENV-W-(envmon) Cover 0 (Main Drawer) is open, from MBM(0,0) Entry 3: At 2002/04/17 19:27:55 ~ENV-W-(envmon) Cover 0 (Main Drawer) is open, from MBM(0,0) Entry 4: At 2002/04/17 19:32:13...
  • Page 120 AlphaServer ES47/ES80/GS1280 Server Management CLI Reference 6. Display using the "-dump" option MBM> MBM> show log -dump -ca 0 -dr 0 mbm Error log from MBM in Cabinet 0, Drawer 0 ------------------------------------------ Entry 0: At 2002/11/25 16:50:10 Text Report 01a37780: 457e003c <...
  • Page 121 Commands 8. Extract events after a given date. MBM> show log -ca 0 -dr 0 mbm –since 2002/04/17 Error log from MBM in Cabinet 0, Drawer 0 ------------------------------------------ Entry 4: At 2002/04/17 19:32:13 ~ENV-W-(envmon) Cover 0 (Main Drawer) is open, from MBM(0,0) Entry 5: At 2002/04/17 19:35:03 ~ENV-W-(envmon) Cover 0 (Main Drawer) is open, from MBM(0,0) Entry 6: At 2002/04/18 19:45:36...
  • Page 122: Show Membership

    AlphaServer ES47/ES80/GS1280 Server Management CLI Reference 3.58 show membership Show membership – display the list of micros in the data base. This command will display all the micros in the data base. The micros listed may not reflect the current set of micros that would be listed as seen in the show network command.
  • Page 123: Show Memory

    Commands 3.59 show memory Displays memory by physical location or by partitioning. By default, this command displays total physical memory, which is based on RIMM size and population. After assigning resources to individual partitions, memory is divided into chunks. Syntax show memory [-physical, -partition] Arguments...
  • Page 124 Total Physical Memory: 32768MB (32.000GB) MBM> 2. Show memory by partitions. MBM> sh mem -part Hard Partition: HP No.= 0 with total physical memory 8192MB (8.000GB) Sub Partition: SP No.=255 with total memory 0MB in 0 chunks: Sub Partition: SP No.=...
  • Page 125: Show Modem

    Commands 3.60 show modem Displays remote management settings. This command displays modem strings, password information, alerts, baud rates, and other server management status. Syntax show modem Arguments None Options None Examples Display remote management status and information. MBM> show modem Remote System Management Settings SM escape sequence : TBD...
  • Page 126: Show Network

    AlphaServer ES47/ES80/GS1280 Server Management CLI Reference 3.61 show network Displays all MBM, PBM, CMM, and CPU IP addresses on the local LAN. Syntax show network Arguments None Options None Example Display the system topology MBM> sh net Cab Drw Module...
  • Page 127: Show Partition

    The "Status" column for IOR lists either "P" or "F", where P indicates that the IOR passed XSROM tests, and F indicates that the IOR failed XSROM tests and was disabled. Syntax [{–hp <hard_partition> [-sp <sub_partition>]}, -all] [-brief] show partition Arguments None Options -hp <hard_partition>...
  • Page 128 Examples 1. List all partitions. MBM> show part ----------------------------------------------------------------- Hard Partition : HP Name = USA_branch, HP No.= 0, SP count = 2 Attributes : max CPUs = 32, SP type = soft, Non-stripe Power State : Power OffPhysical Memory: 8192MB (8.000GB) Community Memory: 0MB (0.000GB)
  • Page 129 Commands MBM> sh part -hp USA_branch -sp hr ----------------------------------------------------------------- Hard Partition : HP Name = USA_branch, HP No.= 0, SP count = 2 Attributes : max CPUs = 32, SP type = soft, Non-stripe Power Stae : Power Off Physical Memory: 8192MB (8.000GB) Community Memory: 0MB (0.000GB)
  • Page 130: Show Power

    AlphaServer ES47/ES80/GS1280 Server Management CLI Reference 3.63 show power Displays the status of power supplies, fans, temperatures and voltages. The VRM status for dual-processor modules are listed under the Power Supply Column. By default, the entire hardware status is shown in summary:...
  • Page 131 Commands DUO1 ..PPPPP..PPP.PP 25.5 30.1 29.6 ..DUO2 ..PPPPP...PPPPP 23.5 31.6 29.6 ..PP..P... PPP..29.0 24.0 ..DUO0 ... .PPPPP..PPPPP 22.5 31.1 30.1 ..DUO1 ... PPPPP...PPPPP 25.0 31.1 29.1 ..DUO2 ...
  • Page 132 AlphaServer ES47/ES80/GS1280 Server Management CLI Reference 3. Show the detailed environment of drawer 0 in cabinet 0. MBM> sh power -ca 0 -dr 0 -detail SBB: cabinet = 0, drawer = 0 Power state: ON Temperatures(in centigrade): MBM: 29.0 (P) OCP: 23.0 (P)
  • Page 133 Commands OCP: 25.0 (P) PS0: 24.0 (P) PS1: ... Fans(in RPM): Fan 0: 2678 (P) Fan 1: 2616 (P) Fan 2: 2721 (P) Power Supplies: PS0: ON PS1: ... Voltages: 2.5V: 2.457V (P) 3.3V: 3.294V (P) 5.0V: 4.915V (P) 1.5V: 1.500V (P) 2.5V: 2.540V (P) 3.3V: 3.294V (P) 5.0V: 5.100V (P)
  • Page 134: Show Sys_Serial_Num

    AlphaServer ES47/ES80/GS1280 Server Management CLI Reference 3.64 show sys_serial_num Displays the system serial number. System serial number is limited to 12 characters and does not apply to RIMMs. Syntax show sys_serial_num Arguments None Options None Examples 1. Show the system serial number.
  • Page 135: Show System

    Commands 3.65 show system Displays a summary of system components. Current status Pass Current status Fail Current status Disabled for RIMMs Past status Pass (currently not powered on) Past status Fail (currently not powered on) Past status Disabled for RIMMs Status unknown (typically status not obtained due to I C error) Not present or not applicable...
  • Page 136 AlphaServer ES47/ES80/GS1280 Server Management CLI Reference Filler .......... PPPP.PPPP. PPPP.PPPP....... PPPP.PPPP. PPPP.PPPP. PCI( 1,4 ).0 ... Filler .......... Filler .......... PPPP.PPPP. PPPP.PPPP. PCI( 1,2 ).0 ... PPPP.PPPP. PPPP.PPPP....
  • Page 137: Show Time

    None Options None Example Show the common base time and delta times of all subpartitions. MBM> sh time Common base time: 2002/04/17 10:59:07 HP Name SP Name Delta Time (Days hh:mm:ss) Default_SP +00 +00:+00:+00 Default_SP -01 -01:-01:-01 MBM> See Also...
  • Page 138: Show Version

    AlphaServer ES47/ES80/GS1280 Server Management CLI Reference 3.67 show version Displays the firmware versions. The firmware modules are CMMFW, CMMFSL, CMMFPGA, SROMFW, XSROMFW, SRMFW, MBMFW, MBMFSL, PBMFW, PBMFSL, PBMFPGA, XSHFPGA, and MBMFPGA. MBMFPGA applies to the ES80 server only. XSHFPGA applies to the XShelf PCI drawer only.
  • Page 139 Commands Examples 1. Display all firmware revisions. MBM> sh ver Local MBM(cab:00, drw:0) FW version X2.2-144 built on Aug 10 2003 at 22:26:07 Cab Drw Micro FW Module Flash Firmware Revision MBMFW X2.2-144 MBMFSL V2.1-1 PBMFPGA* X4.1-01 XSHFPGA* X3.1-03 CMMFW* T2.3-2 CMMFSL* V2.1-22...
  • Page 140 AlphaServer ES47/ES80/GS1280 Server Management CLI Reference SRMFW* X6.6-2914 MBM> 2. Show the firmware version by cabinet amd drawer:. MBM> sh vers -ca 0 -dr 0 mbm Local MBM(cab:00, drw:0) FW version X2.2-144 built on Aug 10 2003 at 22:26:07 Cab Drw Micro...
  • Page 141: Telnet

    Commands 3.68 telnet Log in to a remote host. Users can telnet to the Vxworks shell (port 322) or CLI session of a remote MBM/PBM. Syntax telnet <ip_address> [port] Arguments ip_address IP address of MBM or PBM port The port number to connect to. The default is 23. Options None Examples...
  • Page 142 AlphaServer ES47/ES80/GS1280 Server Management CLI Reference 3. Telnet to a Vxworks shell for debugging, then exit MBM> telnet 10.1.0.1 322 Connecting to 10.1.0.1. Exit sequence is ^[^[MBM. 10.1.0.1->logout Closed connection. MBM> See Also logout, connect, hangup 3-118...
  • Page 143: Test

    In order to run an individual test, a partition must be reset or powered on to XSROM level. Syntax test <test_num> [ {[-cabinet <cabinet> -drawer <drawer>] CPU<n>}, {-ew <ew_coord> -ns <ns_coord> CPU}, {-hp <hard_partition> } ] [<parameters>…] [-p <pass_count>] Arguments test_num A diagnostic test number.
  • Page 144 AlphaServer ES47/ES80/GS1280 Server Management CLI Reference 2. Run test 13 on all CPUs in the hard partition Default_HP MBM> test 13 Running test 13, RAID channel Test ... on 2 EV7s [2003/04/18 15:22:38] ~DIA-W-(pco_04) Test 13 [RAID channel Test] failed on cpu [NS: 0 EW: 0] which i0...
  • Page 145: Test Alert

    Commands 3.70 test alert Tests the modem setup and connection. This command simulates an alert condition by immediately sending an alert. The modem must already be initialized and the sending of alerts must be enabled before this command can be issued. Syntax test alert Arguments...
  • Page 146: Test Led

    AlphaServer ES47/ES80/GS1280 Server Management CLI Reference 3.71 test led Tests all IP and IO cable port LEDs. This command turns the cable LEDs on or off. Setting it for 0 seconds turns the LEDs off. The default is to blink the LEDs for 60 seconds. The maximum is 3600 seconds.
  • Page 147: Update

    NOTE: This command uses TFTP communication between the MBM (which requests the image), and a connected PC (which servers the image). The individual update images are included on the AlphaServer ES47/ES80/GS1280 Firmware CD. The PC must be connected to the Server Management hub via an Ethernet adapter. This connection can be static using the address "10.253.0/254"...
  • Page 148 AlphaServer ES47/ES80/GS1280 Server Management CLI Reference If using DHCP, check "Obtain an IP Address automatically”. Start the TFTP Server on the PC by invoking tftpd32.exe. A copy is found on the AlphaServer ES47/ES80/GS1280 Firmware CD, to be copied to a convenient directory on your local PC. Then change the settings to point the directory containing the files to be upgraded.
  • Page 149 Commands 2. Update all MBM and PBM images. MBM> update mbmfw 10.253.0.254 -fi mbm_T2_1_7.bin Update of module MBMFW completed on node 10.0.0.1 Update of module MBMFW completed on node 10.1.0.1 Update of module MBMFW completed on node 10.254.2.0 Update of module MBMFW completed on node 10.254.5.0 Update is complete! MBM>...
  • Page 150: Uptime

    AlphaServer ES47/ES80/GS1280 Server Management CLI Reference 3.73 uptime Displays the elapsed time that micros have run since initialization. This command currently displays the up time of all MBMs and PBMs. Syntax uptime [-cabinet <cabinet_num> -drawer <drawer_num> ] Arguments The MBM micro (optional).
  • Page 151: Index

    Index reset ........... 3-59 Alerts save partition ........3-63 disable alert........3-30 set............3-64 enable alert ........3-34 set alert..........3-65 assign component command....3-3 set baud..........3-66 assign memory command ....... 3-5 set dial ..........3-67 set escape .......... 3-68 bootline command ........
  • Page 152 AlphaServer ES47/ES80/GS1280 Server Management CLI Reference examine command ........ 3-37 set membership ........3-71 set password command......3-73 halt in command ........3-39 set sys_serial_num command ....3-74 halt out command ........3-41 set time command........3-75 hangup command ........3-43 show cable command ......

This manual is also suitable for:

Alphaserver es80Alphaserver gs1280

Table of Contents