•
"INTERIM RECOVERY MODE"
•
"READY FOR RECOVERY"
•
"RECOVERING"
•
"WRONG PHYSICAL DRIVE REPLACED"
•
"PHYSICAL DRIVE NOT PROPERLY CONNECTED"
•
"HARDWARE IS OVERHEATING"
•
"HARDWARE HAS OVERHEATED"
•
"EXPANDING"
•
"NOT YET AVAILABLE"
•
"QUEUED FOR EXPANSION"
•
"DISABLED DUE TO SCSI ID CONFLICT"
•
"EJECTED"
•
"ERASING"
•
"UNKNOWN"
Message Id: 24601
Severity: Informational
Log message: Logical drive <logical drive number> configured on array controller
<controller name / slot information> is in a failed state but has had one or more
drive replacements and is now ready to change to a status of "OK". However, this
status change will not occur until the logical drive is re-enabled. Please
re-enable the logical drive either via the HP Array Configuration Utility or by
rebooting the system.
Message Id: 24602
Severity: Warning
Log message: The recovery of logical drive <logical driver number> configured on
array controller <controller name / slot information> was aborted while
rebuilding due to an unrecoverable read error. Physical drive number <physical
drive number> was the replacement drive being rebuilt before the read error
occurred, while physical drive number <physical drive number> is the error drive
which reported the read error.
Message Id: 24603
Severity: Warning
Log message: Due to an unrecoverable read error, the recovery of logical drive %3
configured on array controller <controller name / slot information> was aborted
while rebuilding a physical drive.
The physical drive which was being rebuilt is located in bay <bay number> of box
<box number> which is connected to port <port number> of array controller
<controller name / slot information>.
The physical drive that reported the read error is located in bay <bay number>
of box <box number> which is connected to port <port number> of array controller
<controller name / slot information>.
Message Id: 24604
HP Smart Array errors 116