Severity: Informational
Log message: Surface analysis has repaired an inconsistent stripe on logical drive
<logical drive number> connected to array controller <controller name / slot
information>. This repair was conducted by updating the parity data to match the
data drive contents.
Message Id: 24678
Severity: Warning
Log message: The license key <license key> on array controller <controller name /
slot information> is nearing its expiration date. The license key will expire
in <number of days> day(s).
Message Id: 24679
Severity: Error
Log message: The license key <license key> on array controller <controller name /
slot information> has expired.
Message Id: 24680
Severity: Informational
Log message: The firmware image for Smart Array controller <controller name / slot
information> has changed.
The firmware was flashed from:
Revision: <old revision number>
to
Revision: <new revision number>
Message Id: 24681
Severity: Warning
Log message: Device bus fault occurred on storage box <box number>, port <port
number> of array controller <controller name / slot information>. This may result
in a downshift in transfer rate for one or more hard drives on the bus.
Message Id: 24682
Severity: Informational
Log message: An error log update has occurred for the physical drive with BMIC device
index <device index number> of array controller <controller name / slot
information>.
Message Id: 24683
Severity: Warning
Log message: Array controller <controller name / slot information> has reported an
uncorrectable read error during rebuild operations for logical drive <logical
drive number>. The uncorrectable media defects are between logical block address
<block address 1> and logical block address <block address 2>. The host will be
unable to read some blocks between this address range until the blocks are
overwritten. The logical drive rebuild is continuing so that the volume can regain
fault tolerance. Capacity expansion operations must be avoided while the affected
blocks are unreadable.
Message Id: 24684