HP ProLiant Gen9 Troubleshooting Manual page 194

Hide thumbs Also See for ProLiant Gen9:
Table of Contents

Advertisement

OA: Mismatching I/O was detected on Blade [value:bladeNumber], Mezzanine Card
[value], Port [value].
OA: Mismatching I/O was detected on Interconnect [value], Port [value].
OA: Temperature of I/O module in slot [value:slotNumber] is critical - module
shut down
OA: Unsupported Device in bay #[value:bladeNumber].
OA: Unsupported IO Module in bay #[value:slotNumber].
OA: Unsupported IO Module location in bay #[value:slotNumber].
Log type: LOG_CRIT, Failure type: SW
OA: Blade [value:bladeNumber] management processor firmware upgrade failed.
OA: Error reading Fru Board Info for the LCD.
OA: Error reading Fru information for the LCD.
OA: Error reading Fru Internal Use Area for the LCD.
OA: mgmt: Failed to acquire enclosure semaphore.
Log type: LOG_CRIT, Failure type: Info
OA: Mismatching I/O condition resolved, Blade [value:bladeNumber], interconnect
[value] was removed.
OA: Mismatching I/O was removed on Blade [value:bladeNumber], Mezzanine Card
[value], Port [value].
OA: Mismatching I/O was removed on Interconnect [value], Port [value].
Log type: LOG_NOTICE, Failure type: HW
OA: AC Subsystem Overload - FAILED. Redundant Power: [value]W DC, Present Power
[value]W AC.
OA: Blade [value:bladeNumber] Ambient Temperature Cable fault...state is
CRITICAL.
OA: Blade [value:bladeNumber] Ambient Temperature Cable fault...state is
DEGRADED.
OA: Blade [value:bladeNumber] Ambient Temperature caution...state is CRITICAL.
OA: Blade [value:bladeNumber] Ambient Temperature caution...state is DEGRADED.
OA: Blade [value:bladeNumber] Ambient Temperature Sensor fault...state is
CRITICAL.
OA: Blade [value:bladeNumber] Ambient Temperature Sensor fault...state is
DEGRADED.
OA: Blade [value:bladeNumber] cannot partner with its neighbor.
OA: Blade [value:bladeNumber] Disk Tray is Open...state is CRITICAL.
OA: Blade [value:bladeNumber] Disk Tray is Open...state is DEGRADED.
OA: Blade [value:bladeNumber] FRU memory fault...state is CRITICAL.
OA: Blade [value:bladeNumber] FRU memory fault...state is DEGRADED.
OA: Blade [value:bladeNumber] has integrated blade cross connection, Mezzanine
card [value] is superfluous.
OA: Blade [value:bladeNumber] Internal Temperature caution...state is CRITICAL.
OA: Blade [value:bladeNumber] Internal Temperature caution...state is DEGRADED.