1700 Series - HP ProLiant Gen9 Troubleshooting Manual

Hide thumbs Also See for ProLiant Gen9:
Table of Contents

Advertisement

1624- Power Supply Unplugged – Power Supply X is unplugged
Action: Ensure the power supply is plugged in.
1625- Unsupported Power Supply Configuration – Unsupported Power Supply
Mismatch
Action: Ensure the power supply configuration is valid.
1626- Unsupported Power Supply Configuration – Unsupported Power Supply
detected
Action: Replace the unsupported power supply.
1627- Power Supply Configuration Insufficient
Action: Install one or more power supplies to meet power requirements, or press F9 to enter System Utilities
to override requirements if Power Advisor indicates this is possible.
1628- IMPORTANT: The system contains multiple types of power supplies
...Certain features are not supported and power redundancy may be limited.
Action: No action required. This message can be disabled in RBSU.

1700 Series

1700-Slot X Drive Array - Please replace Cache Module Battery Pack...
...Caching will be enabled once the Battery Pack has been replaced and charged.
Audible Beeps: None
Possible Cause: The battery needs to be replaced and charged.
Action: Replace and charge the battery pack.
1701-Slot X Drive Array - Please install Cache Module Battery Pack...
...Caching will be enabled once the Battery Pack is installed and charged.
Audible Beeps: None
Possible Cause: The battery needs to be installed and charged.
Action: Install and charge the battery pack.
1703 - Slot X Drive Array controller - Memory Self-Test Error - Access to all storage
has been disabled...
...Upgrade to the latest firmware. If the problem persists, replace the Cache Module or Controller.
Possible Cause: The cache module or controller has failed or is experiencing a fault.
Action:
Upgrade to the latest firmware.
HP ProLiant server errors 71

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents