User Action: If the tape is failed, check the tape and all SCSI connections.
Supporting SNMP Trap Data:
sysName
cpqHoTrapFlags
cpqDaCntlrHwLocation
cpqDaTapeDrvCntlrIndex
cpqDaTapeDrvBusIndex
cpqDaTapeDrvScsiIdIndex
cpqDaTapeDrvLunIndex
cpqDaTapeDrvName
cpqDaTapeDrvFwRev
cpqDaTapeDrvSerialNumber
cpqDaTapeDrvStatus
Supporting SNMP Trap Description: "Status is now [cpqDaTapeDrvStatus] for a tape drive."
NT Event ID: 1210 (Hex)0x843504ba (cpqstmsg.dll)
Log Severity: Warning (2)
Event Title: Drive Array Tape Drive Cleaning Required.
Log Message: The tape drive in %4, SCSI bus %5, SCSI target %6 requires cleaning.
SNMP Trap: cpqDa6TapeDriveCleaningRequired - 3044 in CPQIDA.MIB
Symptom: Tape Drive Cleaning Required trap. The agent has detected a tape drive that needs to have a
cleaning tape inserted and run. This causes the tape drive heads to be cleaned.
Supporting SNMP Trap Data:
sysName
cpqHoTrapFlags
cpqDaCntlrHwLocation
cpqDaTapeDrvCntlrIndex
cpqDaTapeDrvBusIndex
cpqDaTapeDrvScsiIdIndex
cpqDaTapeDrvLunIndex
cpqDaTapeDrvName
cpqDaTapeDrvFwRev
cpqDaTapeDrvSerialNumber
Supporting SNMP Trap Description: "Cleaning is needed for the tape drive."
NT Event ID: 1211 (Hex)0x843504bb (cpqstmsg.dll)
Log Severity: Warning (2)
Event Title: Drive Array Tape Drive Replace Cleaning Tape.