Replace any failed processors or reseat any loose processors.
2.

Fatal Global Protocol Error

Audible Beeps: None
Possible Cause: The system experienced a critical error that caused an NMI.
Action: Run Insight Diagnostics
indicated.

Fatal Hub Link Error

Audible Beeps: None
Possible Cause: The hub link interface has experienced a critical failure that caused an NMI.
Action: Run Insight Diagnostics
indicated.
FATAL ROM ERROR: The System ROM is not Properly Programmed.
Audible Beeps: 1 long, 1 short
Possible Cause: The System ROM is not properly programmed.
Action: Replace the physical ROM part.
Fibre Channel Mezzanine/Balcony Not Supported.
Audible Beeps: 2 short
Description: The Fibre Channel adapter is not supported on the server.
Action: Install the supported Fibre Channel adapter.

High Temperature Condition detected by Processor X

Audible Beeps: None
Possible Cause: Ambient temperature exceeds recommended levels, fan solution is insufficient, or fans have
failed.
Action: Adjust the ambient temperature, install fans, or replace the failed fans.
Illegal Opcode - System Halted
Audible Beeps: None
Possible Cause: The server has entered the Illegal Operator Handler because of an unexpected event. This
error is often software-related and does not necessarily indicate a hardware issue.
Action: Run Insight Diagnostics
indicated. Be sure that all software is installed properly.
("HP Insight
Diagnostics" on page 76) and replace failed components as
("HP Insight
Diagnostics" on page 76) and replace failed components as
("HP Insight
Diagnostics" on page 76) and replace any failed components as
Error messages 119