Fatal Front Side Bus Error

Audible Beeps: None
Possible Cause: The processor front-side bus experienced a fatal error.
Action: Run Insight Diagnostics and replace any failed processors or reseat an
loose processors.

Fatal Global Protocol Error

Audible Beeps: None
Possible Cause: The system experienced a critical error that caused an NMI.
Action: Run Insight Diagnostics and replaced failed components as indicated.

Fatal Hub Link Error

Audible Beeps: None
Possible Cause: The hub link interface has experienced a critical failure that
caused an NMI.
Action: Run Insight Diagnostics and replace failed components as indicated.

FATAL ROM ERROR: The System ROM is not Properly Programmed.

Audible Beeps: 1 long, 1 short
Possible Cause: The System ROM is not properly programmed.
Action: Replace the physical ROM part.