ensure that the server is properly functioning. This diagnostic function automatically runs each time the
server is powered on.
These diagnostics, which reside in the BIOS ROM, isolate server-related logic failures and indicate the
board or component that needs to be replaced, as indicated by the error messages. Most server
hardware failures are accurately isolated during POST. The number of tests displayed depends on the
configuration of the server.

POST error indicators

When POST detects a system failure, it will display a POST error message.
Recoverable POST Errors
Whenever a non-fatal error occurs during POST, an error message describing the problem appears
onscreen. These text messages are displayed in normal video (white text on black background). It
shows the details of the error.
In some cases an error message may include recommendations for troubleshooting or require that you
press the Enter key to display recommendations. Follow the instructions on the screen.
It is recommended that you correct the error before proceeding, even if the server appears to boot
successfully. If your system displays one of the messages marked below with an asterisk (*), write
down the code and message and contact your HP Customer Support provider.
When no POST error message is displayed but the server stops during POST, listen for beep codes.
lists the most common POST error messages with their corresponding troubleshooting
Table 23
recommendation.
Table 23
POST Error Messages
Error code
000h
003h
004h
00Ah
00Eh
00Fh
010h
012h
Error message
Description/corrective action
Indicates an error while programming the count register of channel 2
Timer Error
of the 8254 timer. This may indicate a problem with system
hardware. Requires repair of the system board.
CMOS Battery is low. This message usually indicates that the CMOS
CMOS Battery Low
battery needs to be replaced. It could also appear when the users
intentionally discharge the CMOS battery.
CMOS Settings
CMOS settings are invalid. This error can be resolved by using F9 to
Wrong
load optimal default in the Setup Utility.
KBC BAT Test failed
Bat test on keyboard controller failed
The A: drive could not be properly initialized by the BIOS. This
A: Drive Error
message is typically displayed when the BIOS is trying to detect and
configure floppy devices in POST
The B: drive could not be properly initialized by the BIOS. This
B: Drive Error
message is typically displayed when the BIOS is trying to detect and
configure floppy devices in POST
Floppy Controller
The floppy controller initialized failed, the devices could not use
Failure
normally
CMOS Date/Time
The CMOS date and/or time are invalid. This error can be resolved
Not Set
by readjusting the system time in the Setup Utility.