UNIVERGE SV8100
If fractional PRI has the number of ports changed, the Trunk Port number might change if
they become split or fit into an empty gap of trunk ports. For example, if you have a
CD-4COT + PZ-4COT
as 25~36 and the PRI is changed to be eight ports instead of 12 ports, the new trunk port
numbers would be 9~16 because the eight ports can now fix into the gap without being split
ports. Another example, if you have a
and the PRI (8 ports) was assigned as 9~16 and then you change the PRI to be 12 ports
instead of eight, the new trunk ports would be 25~36 because the ports have to be split to
keep the original port numbers, and this is not supported.
If using a CSU/DSU, Program 10-03-13 must be set to 0. If not using a CSU/DSU,
Program 10-03-13 must be set to 1~7 or anything other than 0.
Restrictions for Calling Party Name:
The UNIVERGE SV8100 supports receiving the name from the Network in supported
formats only and cannot send the Calling Name. Refer to
Calling Party
NI-2
4ESS (AT&T Custom)
AT&T5ESS Lucent Custom
DMS-100 (Custom)
DMS-100 (National; ISDN)
Nortel Specification NIX-A211-1

CO Line Service is not supported
ISDN – PRI cannot be configured for CO Emulation
B-Channel to Trunk Association
When an Incoming ISDN-BRI/PRI call is received, the system assigns the lowest trunk
number of the ISDN circuit to the incoming call associated with the B-Channel. When an
Outgoing call is placed using the ISDN-PRI/BRI, the system assigns the Trunk and
B-Channel association according to the chart below. This is based on the Trunk-to-Trunk
Group and Trunk Group Priority assignment in (Program 14-05-01).
ISDN Compatibility
for Trunks ports 1~8 and 17~24 and the PRI (12 ports) was assigned
Names.

Table 2-36 Restrictions for Calling Party Names

Protocols
Nortel Specification NIS-A233-1
CD-4COT + PZ-4COT
Name Delivery Formats
Facility Information Elements
Not Supported
Facility Information Element
Display Information Element
Facility Information Element

for Trunks ports 1~8 and 17~24
Table 2-36 Restrictions for

Issue 7.0
2 - 793

Advertisement

Table of Contents
loading

Table of Contents