The Level 1, Level 2 and Level 3 columns indicate the programs that are assigned when programming
this feature in the order they are most commonly used. These levels are used with PCPro and WebPro
wizards for feature programming.
Level 1 – these are the most commonly assigned programs for this feature.
Level 2 – these are the next most commonly assigned programs for this feature.
Level 3 – these programs are not often assigned and require an expert level working knowledge of
the system to be properly assigned.
Program
Program Name
Number
10-09-01
DTMF and Dial Tone Circuit Setup
14-02-05
Analog Trunk Data Setup – Dial
Tone Detection for Manually
Accessed Trunks
2 - 404
Description/Comments
If dial tone detection is enabled, be
sure to allocate at least one circuit
for dial tone detection [ICM/Trunk
(0) or Trunk (2)].
Enable/Disable dial tone detection
for directly accessed trunks. If
disabled, the system outdials on
the trunks without monitoring for
dial tone.
UNIVERGE SV8100
Assigned Data
1
0 = Common Use
1 = Extension Only
2 = Trunk Only
Default:
Circuit/Resource
01~08 = 1 (Extensions)
Circuit/Resource
09~32 = 2 (Trunks)
Circuit/Resource
33~96 = 0 (Not Used)
Circuit/Resource
97~160 = 0 (Common)
When PZ-BS10 is
installed, 97~160 are
available
0 = Dial Tone
Detection Not Used
1 = Dial Tone
Detection Used
(default = 0)
Dial Tone Detection
Level