Port assignment of the CD-PVAA package depends on the K-CCIS – IP with PVA license.
You must input the license code 6200 in Program10-54 for each slot the PVA-CCIS
package is installed.
When multiple CD-PVAA blades are installed in the same UNIVERGE SV8100, it is
necessary to input Program 10-54 for each slot the K-CCIS – IP with PVA is installed. The
total K-CCIS with PVA call count is limited by the license quantity installed in the system.
The following tables illustrate examples of K-CCIS – IP with PVA licensing and slot
assignments:
Example #1
License Quality: 8
Program 10-54 = 8
Example #2
License Quality: 8
Program 10-54 = 0
Example #3
License Quality: 0
Program 10-54 = 8
Example #4
License Quality: 8
Program 10-54 = 24
Example #1
License Quality: 16
Program 10-54 (slot 4) = 8
Program 10-54 (slot 6) = 8
Example #2
License Quality: 16
Program 10-54 (Slot 4) = 16
Program 10-54 (Slot 6) = 16
The K-CCIS – IP with PVA shares the CO/PBX/Tie/DID trunks available for the system.
K-CCIS – IP with PVA

Table 2-38 CD-PVAA Blade Installed in Slot 6

Can make or receive a total of eight calls.
Can assign eight ports and CD-PVAA blade starts.
Cannot assign ports and CD-PVAA blade does not
start.
Cannot make or receive calls.
Can assign eight ports and CD-PVAA blade starts
Can make or receive a total of eight calls.
Can assign 24 ports and CD-PVAA blade starts
Table 2-39 CD-PVAA Blade Installed in Slot 4 and Slot 6
Can Make or receive a total of 16 calls.
Can assign eight ports and CD-PVAA blade starts.
Can assign eight ports and CD-PVAA blade starts.
Can Make or receive a total of 16 calls.
Can assign 16 ports and CD-PVAA blade starts.
Can assign 16 ports and CD-PVAA blade starts.