FAX/Scanner Diagnostic Tests
Phaser 3010/3040/WorkCentre 3045 Service
Test
Control Panel
Skew
-630 to 630
■
Life
Counter Name
Value
These counter values
are reference only. Do
not use as the official
value.
M/C Total PV
30000
M/C FC PV
-
DEVE
-
Roundtime
XERO
-
Roundtime
M/C DispTime
-
LM/C Pixel
-
M/C
-
ColorEmptyBW
M/C Custom
-
Start
M/C Custom End -
Waste Toner
-
Toner PV
Std.: 700/High:14000
Toner DispTime
-
Toner TDCC
-
Toner Pixel
-
Print
Selecting this menu item prints the parameter values and life
counter values stored in the IOT.
Test
Control Panel
Information
Tests FAX and Scanner components.
Scan Counter
FB: 0x00000000
ADF: 0x00000000
Scanner Maintenance
White Balance
White Balance
Registration
Param.
Parameter
Range
Regi ADF Lead
-2.0 mm ~ 2.0 mm,
in 0.1 mm Steps
Regi ADF Side
-1.0 mm ~ 1.0 mm,
in 0.1 mm Steps
Xerox Internal Use Only
Error Troubleshooting
Test Description
Adjusts the skew so that the image is
parallel with both sides of the paper.
Description
Displays the scan counter value.
FB: Platen scans
■
ADF: ADF scans
■
Reports the result of white balance
which is performed while the printer
powers up.
This function adjusts the registration
parameters of the scanner.
Description
Adjusts Registration of the ADF
leading edge.
Adjusts Registration of the ADF side
edge.
2-29