Error Troubleshooting

Entering Service Diagnostics

Exiting Service Diagnostics

2-24
For Phaser 3010/3040:
Use the CE Diagnostic software described in "Using CE Diagnostic Software" on
page A-2.
For WorkCentre 3045:
Use the embedded diagnostic or CE diagnostic software. To activate the
embedded diagnostics:
1. Turn the printer Off.
2. Press and hold the Up Arrow and Down Arrow buttons simultaneously and
turn the printer On.
3. Release the buttons when CE Mode Please Wait... appears on the LCD.
4. The diagnostics are ready when the display reads:
CE Mode
Printer
Fax/Scanner
MFG Settings
Use the Up and Down Arrow buttons to move through the menus. Press OK to
select a menu item. Press the Back button to move up one level in the menu.
To exit Diagnostics mode:
1. Scroll to Fax/Scanner > Complete, press OK.
2. Press OK when Complete Exit Fax/Scanner Diag is displayed.
3. Press OK when Exit Fax/Scanner Diag Start is displayed.