Alcatel OmniSwitch 6624 Network Configuration Manual page 325

Hide thumbs Also See for OmniSwitch 6624:
Table of Contents

Advertisement

Managing Authentication Servers
Switch VLAN number client joins in multiple authority mode (0=single authority; 2=multiple author-
ity); variable-length digits.
Switch slot number to which client connects: nn
Switch port number to which client connects: nn
Switch virtual interface to which client connects: nn
AccountStopTime
User account stop times are tracked in the AccountStopTime attribute that keeps the time stamp and
accounting information of successful user log-outs. The same fields as above (separated by carriage
returns "|") are contained in the Logout log. A different carriage return such as the # sign may be used in
some situations. Additionally, these fields are included but apply only to the Logout log:
Fields For Any Type of Authentication
Log-out reason code, for example LOGOFF(18) or DISCONNECTED BY ADMIN(19)
User account ID or username client entered to log-in: variable length digits.
Fields For Layer 2 Authentication Only
Number of bytes received on the port during the client's session from log-in to log-out: variable length
digits.
Number of bytes sent on the port during the client's session from log-in to log-out: variable length
digits.
Number of frames received on the port during the client's session from log-in to log-out: variable
length digits.
Number of frames sent on the port during the clients session from log-in to log-out: variable length
digits.
AccountFailTime
The AccountFailTime attribute log records the time stamp and accounting information of unsuccessful
user log-ins. The same fields in the Login Log—which are also part of the Logout log (separated by
carriage returns "|")—are contained in the Login Fail log. A different carriage return such as the # sign
may be used in some situations. Additionally, these fields are included but apply only to the Login Fail
log.
User account ID or username client entered to log-in: variable length digits.
Log-in fail error code: nn. For error code descriptions refer to the vendor-specific listing for the
specific directory server in use.
Log-out reason code, for example PASSWORD EXPIRED(7) or AUTHENTICATION FAILURE(21)
OmniSwitch 6624/6648 Network Configuration Guide
April 2004
LDAP Servers
page 17-23