Figure 3-6 Load Connections In Remote Sensing Mode - Ametek Sorensen XG Operation Manual

Programmable dc power supply 670 watts – 1700 watts
Table of Contents

Advertisement

Connecting to the Load in Remote Sensing Mode
CAUTION: Equipment damage
Do not connect sense lines through relays.

Figure 3-6 Load Connections in Remote Sensing Mode

M370430-01 Rev B
Connect the negative (-) output terminal of one power supply to the
positive (+) output terminal of the next power supply. The more
positive supply's positive sense line should connect to the positive
terminal of the load (or distribution point). Its return sense line
should connect to the connection between the two units at the same
spot as the negative supply's positive sense line. The return sense
line of the negative supply should be connected to the return of the
load. See Figure 3-6.
Local Operation
3
3-49

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sorensen xtrSorensen xg seriesSorensen xtr series

Table of Contents