Using Scpi Commands - Ametek Sorensen XG Operation Manual

Programmable dc power supply 670 watts – 1700 watts
Table of Contents

Advertisement

SCPI Command Reference

Using SCPI Commands

CALibration:CURRent:LEVel {<current>|MIN|MAX}
A-4
This Manual shows SCPI commands in the following format:
The command is expressed as a mixture of upper- and lowercase
letters. The uppercase letters suggest how the command can be
abbreviated into a short form. SCPI commands can be sent in long
or short forms. The short form is better for data entry. The long
form is better for readability.
Command strings are not case sensitive:
are all acceptable abbreviations for
CURRENT
Current
,
, and
possible to write for example,
extra first node does not explicitly match the short or long form of
the calibration node.
The command strings include punctuation. While some
punctuation is sent with the string, other markings are used to
identify different elements of the command syntax and are not sent
with the string.
The following punctuation is sent with the command string:
Colons (:) separate command keywords from lower-level
keywords. For example,
Blank spaces separate command keywords from parameter values.
CURR
0.1.
For example,
Commas separate parameters from each other when more than one
parameter is sent in the same string. For example,
OFF,"1234."
Semicolons (;) separate multiple commands from the same
subsystem. This allows for greater efficiency.
For example: CAL :CURR:LEV MIN;VOLT:LEV MIN
is the same as typing:
CAL:CURR:LEV MIN
CAL: VOLT: LEV MIN
Colons and semicolons can be used together to link commands
from different subsystems. For example:
CAL:CURR:LEV MIN;:MEAS:CURR?
The short form is made up of 3 or 4 letters. There can only be a
absolute short or long form. For example, it is not possible to write
CALibrat: CURR: LEV because the extra the first node does not
match explicitly the short or long form of the calibration node.
CURR, Curr,
CURRent
. As for the long form,
current
are all acceptable. It is not
CALibrat: CURR: LEV
CAL : CURR: STAT.
M370430-01 Rev B
and
curr
because the
CAL: STAT

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sorensen xtrSorensen xg seriesSorensen xtr series

Table of Contents