Defining the OVP Set Point

To define the OVP set point:
1.
2.
3.
4.
5.
Important: The OVP range is variable from V SET +5% to V MAX +25%.
6.
The SCPI command (s) for these instructions are:
[[:]SOURce[<channel>]]:VOLTage:PROTection[:OVERvoltage]
[:LEVel]
M370430-01 Rev B
Turn the power supply On.
Ensure the voltage is lower than the desired set point.
Set the output to the desired voltage.
OVP can be set without setting desired output voltage first.
Turn the 9-position mode control to the PRT position.
 is displayed.
Press the rotary Adjust/Enter control.
Turn the rotary Adjust/Enter control to set the upper limit
protection. See "Coarse and Fine Adjustment Modes" on
page 3-3.
Once the desired value has been set, press the rotary
Adjust/Enter control to commit the setting.
If the output is between OVP
is possible when in APG mode.
Local Operation
and -5%, an OVP warning message
set
3
3-29