Analog Programming (APG) and Isolated Analog Programming (ISOL)

Isolated Analog Programming Mode (ISOL)

See "Rear Panel Connectors on 850 Watt Models" on page 1-7 "Rear
Panel Connectors on 1500 and 1700 Watt Models" on page 1-9 for more
details about connections.

AUX Output and Isolated Analog Programming (ISOL) Connector

Function
Auxiliary +5 V and +15 V outputs
OUTPUT ENABLE Aux
Power On Status (output)
SD—Shutdown (input)
Interlock
ISOL programming and monitoring
Figure 4-10 AUX Output and ISOL Connector Pinout
4-20
The AUX Output and Isolated Analog Programming (ISOL)
Connector is a 15-pin female DSUB connector. See Figure 4-10.
All pins on this connector are electrically isolated from the output
of the power supply.
The AUX Output and ISOL Connector provides access to the
following functions:
IS_VOL_PR_V
OL
IS_VOL_PR_C
UR
IS_MON_VOL
AUX1 (+5V)
S_MON_CUR
INTER_LOCK_1
INTER_LOCK_2
MAIN_PS_GOO
D
XG/XTR1500 and
1700
standard
standard
optional
optional
optional
optional
COM_ISOLATE
D
AUX1_&_AUX2
_On/Off
ISO_CUR_RES_P
R
COM_ISOLATE
D
ISO_VOL_RES
_PR
AUX2 (+15V)
SD (Shutdown Main O/P)
M370430-01 Rev B
XG/XTR850
standard
standard
standard
standard
standard
standard