Table A-3
SCPI Commands for Output Control
Function
SCPI Command
[[:]]SOURce[<channel>]]:COMBine:CSHare
Set Current
[: MODE]
Sharing Mode
[[:]SOURce[<channel>]]:CURRent[:LEVel]
Set
[:IMMediate][:AMPLitude]
(Immediate)
Current Set
point
[:]SOURce:POWer:LEVel
Set Constant
1
Power
Set
point
[:]SOURce:POWer:MODe
Set Constant
1
Power Mode
[[:]SOURce[<channel>]]:VOLTage[:LEVel]
Set
[:IMMediate][:AMPLitude]
(Immediate)
Voltage Set
point
[[:]SOURce[<channel>]]:VOLTage:PROTect
Set Over
ion[:OVERvoltage][:LEVel]
Voltage
Protection
Level
[[:]SOURce[<channel>]]:VOLTage:PROTect
Set Under
ion:UNDer[:LEVel]
Voltage
Protection
Level
1
version 2.21 and higher
Parameter and
Description
Range
Set the unit to operate in the
?|CONTroller
current share controller or
|SLAVe
slave mode. If only a single
unit is being used it should be
set to controller.
Set current set point
?|<Current Set
(immediate)
Point>|MAXimum|
MINimum
Set constant power set point
?|<Power Set Point> Yes
(immediate)
Set constant power mode
?|ON|OFF
(Enable/Disable)
Change voltage set point
?|<Voltage Set
(immediate)
Point>|MAXimum|
MINimum
Set the over voltage
?|<OVP Set
protection level.
Point>|MAXimum|
MINimum
Set the under voltage
?|<UVP Set
protection level.
Point>|MAXimum|
MINimum
Query
Yes
Yes
Yes
Yes
Yes
Yes