1. Current: 0.51A minimum guaranteed, 0.72A typically available. Overcurrent protection (each output) is automatic, non-latching. When OCP is tripped the aux voltage folds back and will
recover to nominal condition when the over current condition is removed (typ. < 0.2A).
To protect external circuits attached to the aux outputs it is recommended that customers use an appropriately rated fuse in series with the aux outputs being used.
2. Time for the output voltage to recover within 0.5% at its rated output for a load change 10–90% of rated output current. Output set point 10–100%.
3. For floating chassis ground applications, please contact applications engineering for system design assistance.
+5V: +0.4V, – 0.5V at 0.4A
+15V: +1.2V, – 1.4V at 0.4A
100 PPM/° C from rated output voltage, after a 30-minute warm-up
0.05% of rated output (over an 8 hour interval with constant line, load and temperature, after a 30-minute warm-up)
Typical 20 ms at any rated input line.
Less than 1 ms for 6 V to 60 V models. Less than 2 ms for 80 V to 600 V models
0.5% of actual output voltage or current ± 1 count