Remote Operation Programming - Ametek Sorensen XG Operation Manual

Programmable dc power supply 670 watts – 1700 watts
Table of Contents

Advertisement

Remote Operation Programming

Table C-4
Remote Operation Programming
Programming Mode
Voltage and Current Output Voltage Programming
Votage and Current Output Resistive Programming
Output Voltage and Current Monitor
1
Voltage Programming Accuracy
1
Current Programming Accuracy
Voltage Readback Accuracy
Current Readback Accuracy
Isolation (Prog and Readback Lines)
Voltage and Current Programming Resolution
Voltage and Current Readback Resolution
Parallel Operation
Series Operation
Constant Voltage (CV)/Constant Current (CC) Indicator
2
Shutdown Control
OUTPUT ENABLE Auxiliary Control
Power Supply Status Signal
Interlock Enable/Disable
1. Typical APG or isolated APG accuracy can be improved to max accuracy by user calibration at the specific range selected.
2. The shutdown input has user selectable negative logic operation via front panel or remote digital input/output.
APG
ISOL
0–100%. Voltage control range is 0.0 to 2.0-10.0V in 0.1V increments.
0-100%. Resistive control range is 0.0 to 2.0 - 10.0K in 0.1K increments.
0-100%. Output voltage monitor range is 0.0 to 2.0 - 10.0V in 0.1V increments.
± 0.5% of rated output voltage, max. (0 to 4.0V / 4K Ohm range) ±
0.5% of rated output voltage, typical in other ranges
± 1.0% of rated output current, max. (0 to 4.0V / 4K Ohm range) ±
1.0% of rated output current, typical in other ranges
± 1% of range full scale
± 1% of range full scale
With respect to:
With respect to chassis potential:
chassis potential: 600 V .
500 V
negative or positive main output: 1500 V .
Up to 4 units in master/slave mode Up to 4 units in master/slave mode
Up to 2 units (with external
diodes)
CV: TTL High (4–5 V)
CC: TTL Low (0–0.6 V)
Logic low 0.0 - 1.4V
Logic high 2.0 - 15V Dry
contact compatible
TTL level or dry contact compatible
TTL high: OK (4–5 V)
TTL low: fail (0–0.6 V)
Dry contact. Open/Short: On or Off,
programmable
Digital
±0.1% of rated output voltage
±0.2% of rated output current
±0.1% of rated output voltage
±0.2% of rated output current
0.012% of full scale
Up to 4 units in master/slave mode