Non-Isolated Analog Programming Calibration; Non-Isolated Voltage Monitoring Calibration; Non-Isolated Current Monitoring Calibration - Ametek Sorensen XG Operation Manual

Programmable dc power supply 670 watts – 1700 watts
Table of Contents

Advertisement

Calibration and Troubleshooting

Non-isolated Analog Programming Calibration

Prior to this, the main output must be calibrated first.
Important: In calibration commands, when + or - keys are expected, any other
key will exit from the calibration mode.

Non-isolated Voltage Monitoring Calibration

Important: For maximum accuracy at a specific APG level, follow the
calibration procedure again but use the intended operating voltage level in steps
3 and 8.
To calibrate the non-isolated voltage monitoring:
1.
2.
3.
4.
5.
6.
7.
8.
9.

Non-isolated Current Monitoring Calibration

Important: For maximum accuracy at a specific APG level, follow the
calibration procedure again but use the intended operating voltage level in steps
3 and 9.
7-10
Disconnect the load and connect the voltmeter to the output.
Connect the voltmeter to the non-isolated voltage monitoring
output lines (J1.13 - J1.7).
Set the Voltage APG level to 4 V. Send the SCPI command:
SYST:COMM:APR:LEV
Set the input source as Local. Send the SCPI command:
SYST:REM:SOUR
Set the main output voltage to 100% by sending the
command:
SOUR:VOLT
<ModelVolt>
or use the rotary adjust/Enter control.
Turn the main output On by pressing the OUTPUT ENABLE
Main button on the front panel or send the command:
:OUTP
ON
The OUTPUT ENABLE Main button will illuminate.
Enter interactive calibration mode by sending the SCPI
command:
CAL:MON
Press on the terminal keys - or + to reduce or increase
monitoring value. Adjust the monitoring value displayed on
the voltmeter that was set up in Step 1 to read as close as
possible to 4.000 V.
Press any key other than the + or - keys to exit from
interactive calibration mode.
4
LOC
M370430-01 Rev B

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sorensen xtrSorensen xg seriesSorensen xtr series

Table of Contents